background image

4

1.2  Restrictions

PROHIBITED

–  Do not modify and/or attempt to 

repair the product. All repairs must 

be performed exclusively by au-

thorised personnel.

–  Do not leave the device exposed to 

atmospheric agents.

–  Do not place the device near to heat 

sources or expose it to direct sun-

light.

–  Do not install the device near oth-

er electrical equipment as this may 

lead to signal disturbance.

–  Do not open and/or replace the 

battery.

–  Do not use solvents to clean the de-

vice.

–  Properly dispose of packaging ma-

terial and keep it out of children’s 

reach as it may represent a hazard. 

Disposal must be performed in line 

with applicable laws.

–  Do not dispose of the device as do-

mestic waste.

1.3  Device description

Arrow

WAN

 MVM is a compact radio module 

for 

Maddalena series MVM and MVM Plus 

C water meters that enables measurement, 

transmission and remote reading of the 

consumption values and alarms using wire-

less technology.

Arrow

WAN

 MVM is available in two versions: 

Arrow

WAN

 MVM 169 and Arrow

WAN

 MVM 868

The  two  versions  differ  for  their  transmis-

sion frequency (respectively 169 MHz and 

868 MHz) and for the protocol used.

Arrow

WAN

 MVM 169 uses the wM-Bus trans-

mission protocol and also conforms to AF-

NOR E17Z v2.

Arrow

WAN

 MVM 868 uses the LoRa protocol 

and is certified by LoRa Alliance®.

This guarantees a high level of interopera-

bility with various reading systems on the 

market, including third-party systems.

Summary of Contents for ArrowWAN MVM LoRaWAN 868

Page 1: ...LATION USE AND MAINTENANCE ArrowWAN MVM Translation of the original instructions Before installing and using the device carefully read this manual and store it together with the product wM Bus 169 MHz...

Page 2: ...a it Warranty limitations Maddalena S p A declines all responsibili ty with immediate invalidation of the war ranty in relation to Damage or defects caused by transport or loading unloading Incorrect...

Page 3: ...ts where it will be exposed to atmospheric agents The device must always be pro tected from extreme humidity and heat Penetration of humidity and intense heat may damage the bat tery and the device If...

Page 4: ...n line with applicable laws Do not dispose of the device as do mestic waste 1 3 Device description ArrowWAN MVM is a compact radio module for Maddalena series MVM and MVM Plus C water meters that enab...

Page 5: ...design are internal sensor that identifies rotation of the pointer on the meter using the prin ciple of induction immune to magnetic interference calculates the volume in both directions manages alarm...

Page 6: ...module ArrowWAN MVM 2 3 4 ARROW MVM169 WAN Maddalena S p A Via G B Maddalena 2 4 33040 Povoletto UD IT S N MAD0078799444444 P N 1 ETRMD 0601 1 1870028654 ARROW MVM169 WAN Maddalena S p A Via G B Madd...

Page 7: ...SF7 12 BW125 500 CR 4 5 ArrowWAN MVM 169 WMBUS N2 a b c d e f Frequency ArrowWAN MVM 868 863 at 876 MHz ArrowWAN MVM 169 169 400 MHz at 169 475 MHz Range in an urban context ArrowWAN MVM 868 up to 3...

Page 8: ...nd stored d PROHIBITED Packaging material must be prop erly disposed of and kept out of children s reach as it may repre sent a hazard Disposal must be performed in line with applicable laws 2 2 Fitti...

Page 9: ...e relevant housing 2 Lower the module and offset it Attach the eyelet 3 to the catch 4 and realign the module 3 4 l WARNING Do not apply pressure to force the eyelet in Fasten the module using the scr...

Page 10: ...e radio module stores the volume record ed via an inductive sensor The module is set up in the factory with initial volume at zero If the meter on which the radio module is installed has a reading oth...

Page 11: ...peat the login 2 During activation 3 parameters are re quested the serial number of the mechani cal meter the pulse weight and the reading of the volume measured by the meter ex pressed in litres Once...

Page 12: ...ode l WARNING The Collect mode parameter is set by default to Fixed If module ArrowWAN MVM 169 is activated the radio type can be set to Fixed AMR mode for fixed network Mobile mobile reading mode or...

Page 13: ...tion to verify that the module serial number reading and pulse weight values have been entered correctly From the Install menu click Summary 1 to view the information of the installed modules 2 1 2 Cl...

Page 14: ...s that have a weak NFC antenna the operation could be difficult or impossible Try with a different phone model Module activation error No or difficult connec tion to the NFC port Place the smartphone...

Page 15: ...Click on UNINSTALL 2 Place the smartphone above the radio module to allow the NFC communication Click on START UNINSTALL 3 1 2 3 Wait for the deactivation 4 to terminate 4 Once completed the Uninstall...

Page 16: ...f the electronic board in stand by mode transmitter consumption and num ber of transmissions performed Battery life depends largely on the frequen cy of data transmission set 4 2 Cleaning No particula...

Page 17: ...17...

Page 18: ...18...

Page 19: ...19...

Page 20: ...right to change its products at any time and without prior notice with the aim of improving them and without compromising primary features All the graphic illustrations and or photographs appearing i...

Reviews: