background image

4

1.2  Restrictions

PROHIBITED

–  Modify and/or attempt to repair the 

product. All repairs must be per-

formed exclusively by authorised 

personnel.

–  Leave the device exposed to atmos-

pheric agents.

–  Place the device near to heat sourc-

es or expose it to direct sunlight.

–  Install the device near other electri-

cal equipment as this may lead to 

signal disturbance.

–  Open and/or replace the battery.
–  Use solvents to clean the device.
–  Incorrectly dispose of packaging 

material and keep it out of chil-

dren’s reach as it may represent 

a hazard. Disposal must be per-

formed in line with applicable laws.

–  Dispose of the device as domestic 

waste.

1.3  Device description

Arrow

EVO

 Standalone is a radio module with 

pulse input compatible with 

Maddalena 

water meters and with those of other 

brands. The device allows for measuring, 

transmitting and remotely reading the con-

sumption values and the alarms using a 

wireless transmission technology.

The following alarms are managed: maxi-

mum flow exceeded (limit can be activated 

and configured), backflow (limit set and con-

figurable), leak and mechanical fraud (cable 

cutting).

Arrow

EVO

 Standalone is compliant with the 

wM-Bus data communication protocol de-

fined  at  European  level  by  Standard  EN 

13757. This guarantees a high level of inter-

operability with various reading systems on 

the market, including third-party systems.

Arrow

EVO

  Standalone  is  also  OMS  certified 

(www.oms-group.org).

The factory set-up can be modified via radio 

signal at a later point using the special con-

figuration  kit  (USB  transceiver  and  relative 

software), supplied separately.

The main technical specifications of the 

Ar-

row

EVO

 Standalone design are:

– 

input via four-pole cable of the follow-

ing signals:  pulses  (flow  meter  revolu-

tions),  flow  direction,  anti-fraud,  earth. 

Thanks to these data, the module calcu-

lates the volume (both directions), man-

ages alarms and memorises the data in a 

non-volatile memory;

– 

M-Bus (EN 13757) 868 MHz radio wire-

less communication interface that 

allows remote reading in both mobile 

(walk-by)  and  fixed  (AMR)  scenarios, 

using the same factory set-up (trans-

mission interval);

– 

lithium battery that guarantees long-

term power supply (15 years + 1)

– 

support ring nut that allows the module 

to be attached to the QuadraPlus sensor 

easily. Alternatively, it can be fixed to the 

wall using the two plugs supplied or to the 

pipe using clamps.

Summary of Contents for Arrow EVO Standalone

Page 1: ...ONS FOR INSTALLATION USE AND MAINTENANCE ArrowEVO Standalone Translation of the original instructions Before installing and using the device carefully read this manual and store it together with the p...

Page 2: ...website www maddalena it Warranty limitations Maddalena S p A declines all responsibili ty with immediate invalidation of the war ranty in relation to Damage or defects caused by transport or loading...

Page 3: ...ts where it will be exposed to atmospheric agents The device must always be pro tected from extreme humidity and heat Penetration of humidity and intense heat may damage the bat tery and the device If...

Page 4: ...nical fraud cable cutting ArrowEVO Standalone is compliant with the wM Bus data communication protocol de fined at European level by Standard EN 13757 This guarantees a high level of inter operability...

Page 5: ...for this association performed during installa tion the serial number of the mechanical meter and the serial number of module ArrowEVO Standalone 1 1839012370 A ARROW EVO P N 1 ETRMD 0001 S N 1234567...

Page 6: ...U 2017 2102 OMS Radio Standard Wireless M Bus OMS Modes C1 Default T1 Optional Operating frequency range 868 0 868 6 868 7 869 2 MHz Radiated power max 14dBm Range 500 m in line of sight Reference sta...

Page 7: ...C 10x 10x l WARNING The instruction manual is an inte gral part of the device and should be carefully read and stored d PROHIBITED Packaging material must be prop erly disposed of and kept out of chil...

Page 8: ...external pulse genera tor by appropriately connecting the wires The ArrowEVO Standalone module is sup plied with a four pole cable with earth 1 White pulse input Pulse signal for both the delivery an...

Page 9: ...pos sible Fix the ring nut 1 to a pipe 2 using a clamp or to a wall 3 using the plugs provided Insert the module fully into the guide Preferably install the module with the antenna symbol 4 facing up...

Page 10: ...f zero If the meter on which the radio module is installed has a reading other than zero synchronisation of the mechanical meter reading and radio module is recommended using the programming kit Simpl...

Page 11: ...ctivated using the magnetic programming key use the part of the screen shown in the box 1 Once the desired parameters have been set activate programming for initial installation using the button 2 2 1...

Page 12: ...tion and num ber of transmissions performed Battery life depends largely on the frequen cy of data transmission set 4 2 Cleaning No particular cleaning procedures are required However the installation...

Page 13: ...13...

Page 14: ...14...

Page 15: ...15...

Page 16: ...right to change its products at any time and without prior notice with the aim of improving them and without compromising primary features All the graphic illustrations and or photographs appearing i...

Reviews: