3.3  Programming on initial 

installation of the module

The 

Arrow

EVO

 Standalone module is sup-

plied with a series of set-up data already set 

to the default values.

If necessary, during initial installation, once 

the module has been activated, the follow-

ing values can be modified:

–  Radio reading with reading of the me-

chanical meter

–  Mechanical serial number of the relative 

meter

–  Personalised AES encryption key for each 

meter

–  Impulsive weight

The module is programmed using the Radio 

Evo program / Arrow Evo Console from a PC.

To perform programming on initial instal-

lation, once the module has been activated 

using the magnetic programming key, use 

the part of the screen shown in the box (1).

Once the desired parameters have been set, 

activate programming for initial installation 

using the button (2).

2

1

3.4  Troubleshooting

FAULT

CAUSE

SOLUTION

The radio module is not 

transmitting

Electrical or electronic 

devices interfere with 

the signal

Move devices to a sufficient distance 

away
Move the receiver closer

Battery empty

Replace the battery (contact the 

metering operator)

The module is not active Check the activation procedure has 

been applied correctly

The module is transmit-

ting but the data fields 

are not populated

The paired sensor is 

faulty

Contact the metering operator

Faulty module

Contact the metering operator

WARNING!

For a complete list of alarms, please refer to the specific manual.

Summary of Contents for Arrow EVO Standalone

Page 1: ...ONS FOR INSTALLATION USE AND MAINTENANCE ArrowEVO Standalone Translation of the original instructions Before installing and using the device carefully read this manual and store it together with the p...

Page 2: ...website www maddalena it Warranty limitations Maddalena S p A declines all responsibili ty with immediate invalidation of the war ranty in relation to Damage or defects caused by transport or loading...

Page 3: ...ts where it will be exposed to atmospheric agents The device must always be pro tected from extreme humidity and heat Penetration of humidity and intense heat may damage the bat tery and the device If...

Page 4: ...nical fraud cable cutting ArrowEVO Standalone is compliant with the wM Bus data communication protocol de fined at European level by Standard EN 13757 This guarantees a high level of inter operability...

Page 5: ...for this association performed during installa tion the serial number of the mechanical meter and the serial number of module ArrowEVO Standalone 1 1839012370 A ARROW EVO P N 1 ETRMD 0001 S N 1234567...

Page 6: ...U 2017 2102 OMS Radio Standard Wireless M Bus OMS Modes C1 Default T1 Optional Operating frequency range 868 0 868 6 868 7 869 2 MHz Radiated power max 14dBm Range 500 m in line of sight Reference sta...

Page 7: ...C 10x 10x l WARNING The instruction manual is an inte gral part of the device and should be carefully read and stored d PROHIBITED Packaging material must be prop erly disposed of and kept out of chil...

Page 8: ...external pulse genera tor by appropriately connecting the wires The ArrowEVO Standalone module is sup plied with a four pole cable with earth 1 White pulse input Pulse signal for both the delivery an...

Page 9: ...pos sible Fix the ring nut 1 to a pipe 2 using a clamp or to a wall 3 using the plugs provided Insert the module fully into the guide Preferably install the module with the antenna symbol 4 facing up...

Page 10: ...f zero If the meter on which the radio module is installed has a reading other than zero synchronisation of the mechanical meter reading and radio module is recommended using the programming kit Simpl...

Page 11: ...ctivated using the magnetic programming key use the part of the screen shown in the box 1 Once the desired parameters have been set activate programming for initial installation using the button 2 2 1...

Page 12: ...tion and num ber of transmissions performed Battery life depends largely on the frequen cy of data transmission set 4 2 Cleaning No particular cleaning procedures are required However the installation...

Page 13: ...13...

Page 14: ...14...

Page 15: ...15...

Page 16: ...right to change its products at any time and without prior notice with the aim of improving them and without compromising primary features All the graphic illustrations and or photographs appearing i...

Reviews: