11
3.3 Programming on initial
installation of the module
The
Arrow
EVO
Standalone module is sup-
plied with a series of set-up data already set
to the default values.
If necessary, during initial installation, once
the module has been activated, the follow-
ing values can be modified:
– Radio reading with reading of the me-
chanical meter
– Mechanical serial number of the relative
meter
– Personalised AES encryption key for each
meter
– Impulsive weight
The module is programmed using the Radio
Evo program / Arrow Evo Console from a PC.
To perform programming on initial instal-
lation, once the module has been activated
using the magnetic programming key, use
the part of the screen shown in the box (1).
Once the desired parameters have been set,
activate programming for initial installation
using the button (2).
2
1
3.4 Troubleshooting
FAULT
CAUSE
SOLUTION
The radio module is not
transmitting
Electrical or electronic
devices interfere with
the signal
Move devices to a sufficient distance
away
Move the receiver closer
Battery empty
Replace the battery (contact the
metering operator)
The module is not active Check the activation procedure has
been applied correctly
The module is transmit-
ting but the data fields
are not populated
The paired sensor is
faulty
Contact the metering operator
Faulty module
Contact the metering operator
l
WARNING!
For a complete list of alarms, please refer to the specific manual.