ES
FR
EN
IT
20
Madas Technical Manual
- 5|5.3b - REV. 0 of 2
th
Sep 2019
RG/2MCSH - RG/2MBHZ
11.0 - RATING PLATE DATA
The rating plate (see examples above) shows the following data:
• Manufacturer’s name/logo and address (any distributor name/logo)
• Mod.:
= name/model of the device followed by the connection diameter
• PS =
Allowable pressure
• Pe =
Maximum inlet pressure or pressure range at which product operation is guaranteed
• TS
= Temperature range within which product operation is guaranteed
• Pa
= Outlet pressure range
• Wdso (if applicable)
= OPSO calibration range that can be achieved with the spring provided (without replacing any part)
• AC
= Pa Accuracy class
• SG =
Closing pressure class
• AG =
Overpressure block accuracy group
• EN 88-2
= Product reference standard
• Wdsu (if applicable)
= UPSO calibration range that can be achieved with the spring provided (without replacing any part)
• Rv (if applicable)
= Differential range
• year
= Year of manufacture
• Lot
= Product serial number (see explanation below)
• U1823
= Lot issued in 2018 in the 23
rd
week
• 14216
= progressive job order number for the indicated year
• 00001
= progressive number referring to the lot quantity
•
= Compliance with ATEX Dir. followed by the protection mode
•
= Compliance with PED Dir. followed by the no. of the Notified Body
RG/2MCSH
RG/2MBHZ
Mod.: RG/2MCSH DN 50
PS=Pe:0,5-5 bar
TS: -20+60°C
Pa: 0,8-1,5 bar Rv: 0,9-2 bar
AC10 SG10 EN 88-2
year: 2018 Lot:U1823 14216/00001
Via Moratello, 5/7 - 37045
Legnago (VR) - Italy
www.madas.it
0497
II2G
II2D
Mod.: RG/2MBHZ DN 50
PS=Pe:0,5-5 bar
TS: -20+60°C
Pa: 0,8-1,5 bar Wdso: 0,9-2 bar
AC10 SG10 AG10 EN 88-2
Wdsu: 0,45-0,75 bar Rv: 0,9-2 bar
year: 2018 Lot:U1823 14216/00001
Via Moratello, 5/7 - 37045
Legnago (VR) - Italy
www.madas.it
0497
II2G
II2D