18
Power Tolerance Warning
1) When the +5 or +12 VDC power source exceeds the setting for
tolerance warning range.
2) For the +5 VDC standard and a setting of 0.25 V, if the power drops
below 4.75 V or exceeds 5.25 V, a warning beeper will sound.
3) For the +12 VDC standard and a setting of 0.6 V, if the power drops
below 11.4 V or exceeds 12.6 V, a warning beeper will sound.