Factory Presets  

Before the DigitalDoc5 leaves the factory the values are set to the 
following:  

• 

All Temperature Set-Points are set to 50° C.  

• 

Only Fan number 1 has been "turned on" and its' RPM monitoring 
enabled. We will set all the other fans during this set up 
procedure.  

• 

The power tolerance warning range is set at +5% (or +0.25 V) for 
+5 VDC, and for +12 VDC, the range is +0.6 V.  

If you make a mistake when setting the system values, you can change 
all the values back to those of the factory settings. This is accomplished 
by pressing the SET button before the power is turned on. After this, turn 
the power on again and wait until you hear the sound of two beeps, which 
shows that the resetting in complete. Or when the power is on, press the 
RESET button, then press the SET button; afterwards press the RESET 
button again, and the two beeps indicate that the resetting is complete.  

Getting Started  

To begin the set up procedure you need to press the 

Set Button 

on your 

DigitalDoc5. This will bring you into Set-Up mode and will allow you to 
change all the settings according to your setup. At any time, if you do not 
press a button within 5 seconds, the DigitalDoc5 will return to Normal 
Operating Mode and you will have to restart the set up procedure by 
pressing the 

Set Button 

again.  

Here is a basic flow chart outlining the steps involved in setting up your 
DigitalDoc5. Later in this chapter we will go through these Step-By-Step. 
Each time you press the 

Set Button 

you will continue on to the next 

setting. You will use the 

Up 

and 

Down Buttons 

to change the settings 

such as Fan On-Off, RPM Sensing Enabled or Disabled, Temperature 
Levels and Power Tolerance Levels. 

A) 

Celsius (C) or Fahrenheit (F) temperature unit selection.  

B) 

Individual channel set-point selection, starting with the 
temperature setting for channel 1 (CH1) and proceeding through 
the set-points of all channels.  

C) 

Fan rotation monitoring and rotation control setting, starting from 
fan 1 (FAN1). When initially setting the fan rotation control 
function, the screen will display either [En] or [Dis]. 

 

Note:

 [En] indicates that the fan speed monitoring function is on, 

i.e. 

enabled

; [Dis] indicates that it is off for this fan, i.e. 

disabled

.  

Next is the override fan control, with the display showing either 
[On] or [Off]. [On] indicates that the override function is on (i. e., 
the fan is turned on whenever the power is turned on to the unit). 

 

Tip

 

You can leave Set-

Up Mode at any time by 
not pressing any button 
for 5 seconds. All values 
will automatically be  
saved.  

 

Note

 

Have your 

Printable Worksheet in 
front of you when you go 
through the set up 
procedure. It will help you 
throughout the set up 
procedure by showing you 
which fans are RPM 
Sensing or not. 

 

 

Summary of Contents for Digital Doc 5

Page 1: ...DigitalDoc5 5 Thermal Sensor Fan Voltage Monitor User Manual I In ns st ta al ll la at ti io on n G Gu ui id de e...

Page 2: ...ep Instructions 11 o Step 1 Changing Temp Units From Celsius C to Fahrenheit F 11 o Step 2 Temperature Set Points 11 o Step 3 Fan Monitoring and Rotation Settings 12 o Step 4 Power Tolerance Settings...

Page 3: ...as well as the stability of the 5 or 12 VDC power supply In addition you can set the cycle time to automatically scan each channel s temperature fan speed and rotation status If the temperature rises...

Page 4: ...ng electricity use and environmental energy needs Uses EEPROM memory chip to save all settings When equipment is turned on there is no need to re enter settings Unit easily installs in any 5 25 openin...

Page 5: ...5 What s Included The DigitalDoc5 should come with the following DigitalDoc5 Unit Screws 2 types 5pcs each 10pcs Thermal Tape 8pcs Sensors 8pcs...

Page 6: ...ou will want to match them up so if a Temperature Sensor hits your Temperature Set Point the corresponding fan will come on Here is an example of how you would set up one of your fans and Temperature...

Page 7: ...If you followed the tip of marking each sensor s channel attach it to the corresponding Two Pin Connector on the back of the DigitalDoc5 Shown in Fig 2 5 Note Either orientation can be used when conn...

Page 8: ...Cable The DigitalDoc5 Thermal Sensor is designed to connect to a 12 VDC power source no batteries are required One end of the power source cable supplied with the unit is a standard 4 pin female conne...

Page 9: ...u choose different options 2 2 Down Button Same as Up only Down 2 3 Set Button This is the button we need to use now to set up the DigitalDoc5 2 4 Reset Button This will set all the settings back to t...

Page 10: ...by pressing the Set Button again Here is a basic flow chart outlining the steps involved in setting up your DigitalDoc5 Later in this chapter we will go through these Step By Step Each time you press...

Page 11: ...hing C Fig 3 2 or F Fig 3 3 symbol Press the Up or Down Button once to change the units Step 2 Temperature Set Points Press the Set Button again to start selecting the Temperature Set Point values The...

Page 12: ...below 500 B Pressing the Set Button again takes you to that fan s rotation or override setting The LCD displaying On Fig 3 7 or Off Fig 3 8 indicates that you can set the fan s rotation control On wh...

Page 13: ...the tolerance be set at 0 25 V 5 B Press the Set Button again to reach the 12 VDC tolerance setting C Set the 12 VDC tolerance to one of the four range values 0 60 1 20 1 80 and 2 40 V Note Most 12 VD...

Page 14: ...area Each number refers to a given monitoring channel and indicates fan rotation status A lit number indicates that the fan is currently turning a flashing light indicates that the fan is possibly jam...

Page 15: ...ime the button is pressed it goes to the next function When the final function is reached the system will save the values or if you do nothing as mentioned earlier for 5 seconds the system will automa...

Page 16: ...emperature Sensor Channel and displays it for 5 seconds completing a cycle every 40 seconds If you press the Up or Down Buttons the DigitalDoc5 will display the next Temperature Setting value As it cy...

Page 17: ...d off if the temperature in that channel continues to rise another 5 C then the system will activate the warning beeper a second time 4 If the warning beeper is turned off a second time then the syste...

Page 18: ...for tolerance warning range 2 For the 5 VDC standard and a setting of 0 25 V if the power drops below 4 75 V or exceeds 5 25 V a warning beeper will sound 3 For the 12 VDC standard and a setting of 0...

Page 19: ...212 Fahrenheit Number of Temperature Sensors 8 Sensors Temperature Sensor Resistance Between 5 K and 15 K Temperature Sensor Accuracy 1 Degree Maximum Fan Rating 1000mA 1 Amp or 12 Watts per fan conne...

Page 20: ...are memorized even when the computer is shut off Q5 How many fans can the DigitalDoc5 monitor and control A The DigitalDoc5 can control up to four can control up to 8 12 V fans which are activated wh...

Page 21: ...ith the DigitalDoc5 you must make sure that you disable the fan monitor before beginning operation Otherwise the monitor keeps looking for the fan signal and when it does not receive one it then sound...

Page 22: ...orts any 8 x 8 cm and 12 x 12 cm up to 1000mA cooling fans and the length of the sensors extend the full range of the RAID tower Q18 Who would need a DigitalDoc5 A Any system that produces heat would...

Page 23: ...gitalDoc5 in Chapter 3 Setting Up Your DigitalDoc5 5 If the fan does not have RPM sensing then don t check the box You would then disable dIS this fan s RPM Sensing Option in Set Up Mode Copyright 200...

Reviews: