MACH ETH - User Manual
MACH SYSTEMS s.r.o.
Page
9
of
20
4.4.2
Switches
DIP1, DIP2, DIP3 and DIP4
can be used in a user’s application.
DIP switches
Side view
Table 6 User DIP Switches
4.5
CAN Bus Termination
There are no internal termination resistors on either CAN channel inside the device. Therefore,
a proper termination of the CAN bus is needed, and the user has to make sure the CAN bus is properly
terminated at both ends.
Figure 7 CAN Bus Termination
4.6
Inputs and Outputs
The device features one analogue inputs and one digital outputs (PWM capable).
Signal
Direction
Function
Range
Note
AI1
Input
Analogue / Digital Input
0 - 5 V
DO1
Output
Push-pull Digital Output
5 V, max. 0.5 A
PWM capable
Table 7 Inputs and Outputs
A load connected to a digital output pin DO1 may draw significant current. In case digital output are
used in a user application, it is strongly suggested to power the device from
an external power supply
and not over USB. Otherwise, USB power limits might be exceeded.
4.7
USB
Micro-USB connector (X4) uses the standard pinout, and can be used for firmware upload or
in application as a virtual COM port.
4.8
Galvanic Isolation
The device does
not
have any galvanic isolation. The user has to make sure there are no ground loop
in his setup