214079
23
Revision C
1004731
A
B
C
Figure 3.39: Auger Clearance
6.
Loosen two nuts (B).
7.
Use adjuster bolt (A) to set clearance (C) to 5
–
10 mm
(3/16
–
3/8 in.). Turn adjuster bolt (A) clockwise to increase
clearance and counterclockwise to decrease clearance.
NOTE:
The clearance increases 25
–
40 mm (1
–
1 1/2 in.) when
center-link is fully retracted.
8.
Repeat Steps
and
on opposite end of
the auger.
9.
Tighten nuts (B) on both ends of feed auger. Torque nuts to
106
–
118 Nm (79
–
87 lbf·ft).