TYPE MMA MIG TIG
Power voltage (V)
:
230 230 230
Rated input current(A)
:
36 33 25
Output current range(A)
:
20-250 20-250 20-250
No-load voltage(v)
:
65 65 65
Rated output voltang.(V)
:
30 26.5 20
Insulation class
:
F F F
Efficiency(%)
:
85 85 85
Duty cycle (%)
:
60 60 60
Wire Diameter(mm)
:
--- 0.8-1.0 ---
ARC STARTING
:
TOUCH TOUCH HF
Dimension(mm)
:
570*305*518 570*305*518 570*305*518
Installation:
1.
connect the gas cylinder to CO2 input part of machine by gas hose., the gas cylinder should have CO2 gas
pressure reducer.
2.
connect the earth clamp to the connector on the panel
3.
install the welding wire to the bracket.
4.
choose the suitable gloove according to the wire diameter.
5.
insert the wire to the feeder through gose, pls take care to avoid wire bend .
6.
the wire should installed deasil, and use the scew to fix the wire. If the wire is bend ,pls cut off this part .
7.
connect the torch to the socket on the panel, and connect the wire to the torch.
Operation:
1.
locate
“
ON
”
of the air switch . adjust the gas bottle switch, and adjust the flowmeter.
2.
choose the suitable diameter of feeder according to the wire .
3.
choose the suitable contact tip .
4.
adjust the voltage and current according to the workpiece.
5.
press the switch of torch, then the wire can come out, and you can start