M2I TOPRW0700WD-IO Hardware Manual Download Page 3

Industrial HMI Touch Panel Hardware Manual

 

     
 

M2I Corporation 

11-35, Simin-daero 327beon-gil, Dongan-gu, Anyang-si, Gyeonggi-do 14055, Korea, Tel: +82-70-465-3366, Fax: +82-31-465-3355, www.m2i.co.kr 

3 / 22 

 

 

Chapter 1 Safety Precautions 

■  Before using the product 

To use the product safely and effectively, please read the contents of this manual thoroughly before use. Please 
keep  to  the  safety  precaution,  for  it  is  to  prevent  accidents  and  potential  danger  from  occurring.  Safety 
precaution  is  classified  into  ‘Warning’  and  ‘Caution’  and  their  meanings  are  as  follows

Also  the  indicated 

illustrations on the product and in the manual have the following meanings. 

 

Violating the instruction may result in serious personal injury or death. 

 

Violating the instruction may result in slight personal injury or product damage. 

 

Be cautious, for danger may be present. 

 

Be cautious, for there is a possibility of an electric shock. 

 
■  General Precautions 

Do not press the screen with a hard or sharp object (awl, screwdriver, pen) with too strong a force.   
It may cause malfunction of touch due to damage of the front sheet. 
Do not use or store in an environment with high vibration. 
Do not allow foreign objects such as water, liquids, or metal powders to enter the product. This may cause 
breakage or electric shock. 
Do not allow foreign objects such as water, liquids, or metal powders to enter into the product.   
Use the radio or mobile phone at least 30cm away from the main unit. 
Two or fewer bright spots may appear on the LCD screen, and certain areas may appear brighter, but this is 
not a defect in LCD characteristics. 
Do not store or operate in direct sunlight. Direct sunlight can change the properties of the LCD. 
Do not touch an adaptor or power code with wet hands. It can cause electric shock. 
Do not use this product in explosive environments with flammable liquid, gas, or dust. 
If the product needs long-term storage without using, avoid direct sunlight and keep dry condition. 
After this product is installed, the general user should only touch the part exposed on the front during 
operation. 

 

■  Design Precautions 

For protecting whole control system from outer power input or malfunction of product, protection circuit 
must be installed outside of product.

 

Physical  protection  devices  as  emergency  switch,  limit  switch,  or  motion  interlock  circuit  and  others  to 
prevent a critical damage of whole system’s safety and human accident from the product’s malfunction.   
When  computers  or  other  outer  devices  control  (operation  mode  change)  the  product,  set  interlock  in 

sequence program to protect from any communication errors. 

Input/output  signals  or  communication  cables  must  have  at  least  100mm(3.94inch)  distance  from  power 
cable or high-tension wire. Especially communication cables must be set apart from power cables. 

 

■  Wiring Precautions 

Be  sure  the  wiring  is  done  correctly  by  checking  the  product’s  rated  voltage  and  the  terminal  layout. 
Incorrect wiring could result in fire, damage or malfunctions. 
Tighten the terminal screw with the specified torque. If the screws of terminal are loose, it could result in 

Summary of Contents for TOPRW0700WD-IO

Page 1: ...ea Tel 82 70 465 3366 Fax 82 31 465 3355 www m2i co kr 1 22 M2I Corporation Industrial HMI Touch Panel TOPRW0700WD IO Hardware Manual Thank you for purchasing the industrial HMI touch panel series of...

Page 2: ...neral Specifications 7 4 1 TOPRW0700WD IO 7 4 2 Product Dimension 7 4 3 Part Names and General Specifications 8 4 4 Rear Part Names and Specifications 8 Chapter 5 External Device Interface 9 5 1 Seria...

Page 3: ...nit Two or fewer bright spots may appear on the LCD screen and certain areas may appear brighter but this is not a defect in LCD characteristics Do not store or operate in direct sunlight Direct sunli...

Page 4: ...r vibration continuously have impacted on product If the product is left without using in long term it must be recharged and stored in room temperature The space between back of product and back of co...

Page 5: ...rnet which is used for the basic purpose of communication with another device PLC 2 2 Package Contents The components of the product are as follows Before using the product please check that all of th...

Page 6: ...5ms N A Photocoupler Digital Output 11 0Vdc 28 8Vdc 0 5A ON Max 0 3ms OFF Max 0 5ms N A Analog Input AIC 0 20mA AIV 0 5Vdc RTD PT100 200 C 850 C TBD 16 bit Capacitive Analog Output AOC 0 20mA AOV 0 5V...

Page 7: ...gil Dongan gu Anyang si Gyeonggi do 14055 Korea Tel 82 70 465 3366 Fax 82 31 465 3355 www m2i co kr 7 22 Chapter 4 Part Names and General Specifications 4 1 TOPRW0700WD IO 4 2 Product Dimension Model...

Page 8: ...S 232C Serial Comm with PLC 4 COM2 Connector DSUB9 RS 232C 422 485 Serial Comm with PLC Switchable the Comm Via Software 5 ETHERNET Connector RJ45 10BASE T 100BASE TX Auto MDIX 6 USB Connector MINI US...

Page 9: ...Data Type Data Bit 7 8 bit Parity Bit NONE ODD EVEN Parity Stop Bit 1 2 bit Modular Jack DSUB 9pin 5 1 2 RS 422 485 Items Contents Protocol Full Duplex Half Duplex Synch Asynchronous Communication Dis...

Page 10: ...and SDB as Twisted Pair Cable Do not use shield wire of communication line as signal ground It may cause communication failure 5 2 Ethernet Communication Specifications 5 2 1 Ethernet Items Contents...

Page 11: ...ansfer Speed 480Mb s Support Device USB Storage FAT16 FAT32 File Format Available Connector Type Type A 1ch 5 3 2 USB OTG Type Item Specification USB Interface USB 2 0 Communication Method Interrupt B...

Page 12: ...Input 16 DIF F Channel Contact Input 7 DI6 No 6 Channel Contact Input 17 COM Common Terminal Field Power 24Vdc or 0V Connection 8 DI7 No 7 Channel Contact Input 18 COM 9 DI8 No 8 Channel Contact Inpu...

Page 13: ...Power 24VdcV Connection 8 DON7 No 7 Channel Contact Output 18 F24V 9 DON8 No 8 Channel Contact Output 19 F24G Common Terminal Field Power 0V Connection 10 DON9 No 9 Channel Contact Output 20 F24G 6 2...

Page 14: ...0 AGND Analog Ground 6 3 2 Analog Input Output Terminal Specification Item AIC0 AIC1 AIV0 AIV1 AOC0 AOC1 AOV0 AOV1 Number of Inputs 2 channels Input Analog current Type 2 channels Input Analog voltage...

Page 15: ...alog Ground 9 AGND Analog Ground 10 AGND Analog Ground 6 4 2 RTD Input Terminal Specification Item Description Number of Inputs 2 channels analog RTD Type Sensor Type and Input Range PT100 200 0 to 85...

Page 16: ...uch Panel Hardware Manual M2I Corporation 11 35 Simin daero 327beon gil Dongan gu Anyang si Gyeonggi do 14055 Korea Tel 82 70 465 3366 Fax 82 31 465 3355 www m2i co kr 16 22 6 4 3 Rated Input Range an...

Page 17: ...e malfunction and damage 3 Be sure that heat from surrounding equipment does not cause product to exceed its standard operating temperature 4 When you don t see within 30 you may not see clearly When...

Page 18: ...65 3366 Fax 82 31 465 3355 www m2i co kr 18 22 Model A mm B mm C mm TOPRW0700WD IO 197 1 0 0 127 1 0 0 1 6 5 0 1 0 0 3 Clamp Fixing Install clamps with this product should be installed as follows to m...

Page 19: ...roduct tighten the cables with a fixing hole on product side and cable tie Chapter 8 Wiring 8 1 Power Wiring Caution With a power and ground cables wiring using Pin Terminal is important for maintaini...

Page 20: ...of power is as follows 8 2 Ground Wiring 1 The product has enough anti noise measure so except that there are many noises Specially the ground is not needed When doing ground please refer to the follo...

Page 21: ...h is indicated on the product label b Only the authorized worker from M2I Corporation can check and repair problems related to malfunction of the machine c If the problem cannot be solved at the insta...

Page 22: ...Power Specifications TOPRW05 07 24Vdc 12W TOPRW10 24Vdc 15W KC Certificate No Inside Cell Model Name MS920SE Rechargeable lithium Battery irreplaceable Copyright M2I Corporation 2022 06 www m2i co kr...