![M2I TOPRW0700WD-IO Hardware Manual Download Page 17](http://html2.mh-extra.com/html/m2i/toprw0700wd-io/toprw0700wd-io_hardware-manual_4786157017.webp)
Industrial HMI Touch Panel Hardware Manual
M2I Corporation
11-35, Simin-daero 327beon-gil, Dongan-gu, Anyang-si, Gyeonggi-do 14055, Korea, Tel: +82-70-465-3366, Fax: +82-31-465-3355, www.m2i.co.kr
17 / 22
Chapter 7 Installation
7.1 Installation Requirements
(1) For the performance, ventilation and safe use of the equipment, keep the distance between the back of the
main unit and each wall of the container at least 100mm and install the cooling fan when installed in an
enclosed space.
(2) It should be installed within -10 ~ 50°C and 10~80% relative-humidity, otherwise the screen may be
changed or cause malfunction and damage.
(3) Be sure that heat from surrounding equipment does not cause product to exceed its standard operating
temperature.
(4) When you don’t see within 30°, you may not see clearly When installing the product in a slanted position,
The product screen should not incline more than 30°.
(5) In order to minimize external mechanical hazards, please control the mechanical hazards of the surrounding
environment.
7.2 Installation Procedure
In order to install this product, please follow the following procedure.
(1) Panel Cut-out
Make a panel cut which product is mounted and insert the product to the panel form the front side.
(2) The Size of Panel Cut
Making the Panel Cut (Mounting Size) per each TOPRW Series as below Table, Before Installation.
IP65
IP2X
-10 ~ 50°C, 10~80%
-10 ~ 50°C, 10~80%