Ensure electrical cables are long enough to enable the drive unit to be disas-
sembled and removed from the vessel.
q
yes
q
no
Install the AC Motor
Complete
1
Connect the drive unit.
q
yes
q
no
2
Ensure that the supply voltage and overload protection are set. Ensure that the
electrical cover and conduit entries are in place. Ensure that the outer drive
head rotates clockwise (view from above).
q
yes
q
no
Install the DC Motor
Complete
1
Make electrical connections. Make sure the electrical cover and the cable
gland entries are properly in place.
q
yes
q
no
2
Ensure that the motor rotates clockwise (view from above)
q
yes
q
no
Install the Speed Counter (Optional)
Complete
1
Remove the outer drive head from the drive unit.
q
yes
q
no
2
Mount the speed counter on the drive unit according to the illustrations in this
manual for each GMP size.
q
yes
q
no
3
For GMP 2000, 5000, and 10000, ensure the cable is installed correctly.
q
yes
q
no
q
n/a
4
Mount the contact in the contact holder; tighten the contact holder on the
drive unit. Collect leftover cable.
q
yes
q
no
5
For GMP 50, insert an extension plate between the shaft and the outer drive
head.
q
yes
q
no
6
Insert the outer drive head on top of the speed counter unit.
q
yes
q
no
7
Connect the socket cable.
q
yes
q
no
8
Check that the number of pulses per rotation is correct.
q
yes
q
no
Install the Control Cabinet
Complete
1
Select the appropriate control cabinet.
q
yes
q
no
2
Set torque according to AC motor and DC motor.
q
yes
q
no
3
Verify that the correct EPM-prom is installed.
q
yes
q
no
4
If the control cabinet is not supplied by us, install a frequency converter.
q
yes
q
no
q
n/a