1) According to the table above, select an appropriate AC cable, peel off the insulation sleeve of AC cable for 40~60mm, and
peel off the sleeve in the conductor core of 3L/PE/N wires for 8mm.
2) Insert the stripped AC cables through the AC connector cover in the sequence.
3) Put the cord end terminals on the stripped conductors one by one and press with some pressure to make it tightly locked with
the conductors.
Wire Diameter:12-18mm
Strip Length:8mm
40-60mm
Cables
Screw cap
The
insulator
AC sheet cover
BACK-UP
ON-GRID
Single hole seal ring