Energy Butler Hybrid Series
User Manual
40
No.
Color
Meter Side
Battery Side
1
Orange&White
/
RS485_A
2
Orange
/
RS485_B
3
Green&White
RS485_B
/
4
Blue
/
CAN_H
5
Blue&White
/
CAN_L
6
Green
RS485_A
/
7
Brown&White
RS485_B
/
8
Brown
RS485_A
/
METER
RS485
1
2
3
4
5
6
7
8
Communication between inverter and meter
The communication between meter and inverter is an RJ45 interface cable.A 10M length meter communication cable is already
attached to the inverter when you received it and this cable could be extended up to 100M. Insert the RJ45 heads into the meter
RS485 port.
Dismantle the cover of the communication ports with a screwdriver, and put all communication cables through the holes and follow
the illustration below to make the connection of each communication cables, and when all cables have connected, put back the
cover and screw up the anti-water cap of the holes.
RJ45 terminal connection sequence and definition.