background image

R7L-YS2

5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN
Phone: +81(6)6659-8201  Fax: +81(6)6659-8510  E-mail: [email protected]

EM-7804-E  Rev.5  P. 2 / 14

COMPONENT IDENTIFICATION

ERR

SVCE

ONLINE

TX/RX

PWR

0 1 2 3 4 5 6 7 8 9 A B C D E F

4

5

6

7

1

2

3

Reset SW

Factory Configuration Port

Service SW

Status Indicator LED

Indicator LED

L

ON

W

ORKS

, Power Supply

Terminals

Output Terminals

2

3

4

1

5

10

7

8

9

6

 

STATUS INDICATOR LED

ID

COLOR

STATE

MEANING

PWR

Green

ON

Internal 5V is normal

OFF

Internal 5V is abnormal.

ONLINE Green

ON

Online

Blink

approx.

0.5 Hz

Offline
Sending/receiving of Net-
work
Variables has stopped.

Blink

approx.

2 Hz

Receiving Wink Message

OFF

Abnormal state

ERR

Red

ON

Writing in the non-volatile 
memory

Blink

Abnormal state

OFF

Normal state

TX/RX

Green

ON

Sending/receiving Network 
Variables

OFF

Communication is lost.

SVCE

Green

ON

No network information

Blink

approx.

0.5 Hz

Offline
Sending/receiving of Net-
work
Variables has stopped.

OFF

Normal state

 

INDICATOR LED

Used to show network variable status assigned to fbLED.
     

ON  

: LED ON

     

OFF  : LED OFF

 

SERVICE SWITCH

Used to identify the node in L

ON

W

ORKS

 network configura-

tion.

 

RESET SWITCH

Used to reset the Neuron Chip.  Press the switch behind the 
front cover to reset.
Control functions are halted while completing resetting and 
restarting.  Confirm no danger before conducting resetting.

 

POWER SUPPLY, L

ON

W

ORKS

 TERMINAL ASSIGNMENT

4

NET1

5

NET2

6

U (+)

1

NET1

2

NET2

3

FG

7

V (–)

NO.

ID

FUNCTION, NOTES

1

NET1

L

ON

W

ORKS

 communication 1

2

NET2

L

ON

W

ORKS

 communication 2

3

FG

FG

4

NET1

L

ON

W

ORKS

 communication 1

5

NET2

L

ON

W

ORKS

 communication 2

6

U (+)

Power input

7

V (–)

Power input

Note:   L

ON

W

ORKS

 wiring must be paired between NET1 termi-

nals and/or NET2 terminals.

 

OUTPUT TERMINAL ASSIGNMENT

6

NC

7

I0

8

NC

1

NC

2

COM0

3

NC

9

I1

4

COM1

10

NC

5

NC

NO.

ID

FUNCTION

NO.

ID

FUNCTION

1

NC

No connection

6

NC

No connection

2 COM0 Common 0

7

I0

Current 0

3

NC

No connection

8

NC

No connection

4 COM1 Common 1

9

I1

Current 1

5

NC

No connection

10

NC

No connection

Summary of Contents for R7L-YS2

Page 1: ...co jp POINTS OF CAUTION POWER INPUT RATING OPERATIONAL RANGE Locate the power input rating marked on the product and confirm its operational range as indicated below 24V AC rating 24V 10 50 60 Hz appr...

Page 2: ...line Sending receiving of Net work Variables has stopped OFF Normal state INDICATOR LED Used to show network variable status assigned to fbLED ON LED ON OFF LED OFF SERVICE SWITCH Used to identify the...

Page 3: ...6 24 50 1 97 6 24 18 5 73 115 4 53 CONNECTION DIAGRAM 4 7 6 3 2 5 1 V U FG NET2 NET2 NET1 NET1 OUTPUT 0 LONWORKS LONWORKS EXTENSION CONNECTOR 7 I0 2 COM0 9 4 I1 COM1 OUTPUT 1 WIRING INSTRUCTIONS SCRE...

Page 4: ...oemType SCPTserialNumber Extension module setting Maximum sending time per fb Minimum sending time per fb Set Tag No name Indicate Model No and Version Indicate Serial No NodeObject Network Variables...

Page 5: ...0 0 Maximum time interval to send network variables per fb Power supply must be reset when this configuration prop erty is changed Network variables are sent out in the specified intervals even when...

Page 6: ...NTOut Set the maximum count Set the value when fbCNT is reset fbCNT SCPTdirection nviCNTIn SCPTinvrtOut nviCNTCtrl SCPTpwrUpState nvoCNTOut SCPTnvType SCPTmaxRnge SCPTsetpoint Network Variables Config...

Page 7: ...Count always reset to 0 Bit 5 8 through 15 Invalid Minimum input pulse width 500 ms for nviCNTIn 50 ms for the input terminals DO NOT connect a network variable to nviCNTIn when one of the input term...

Page 8: ...the current at Output 0 and 1 Configuration Properties CONFIGURATION PROPERTY NETWORK VARIABLE TYPE Range Default EXPLANATIONS SCPTsetpoint 0 nviYSVal SNVT_lev_percent 15 000 115 000 0 0 nviYSVal low...

Page 9: ...tpoints Network variable type 0 and 100 setpoints nviCVIn SCPTnumDigits SCPTnvType SCPTsetpoint nvoCVOut SCPTnvType SCPTsetpoint Network Variables Configuration Properties nv 62 nv 63 nv 64 nv 65 Netw...

Page 10: ...int 1 nviCVIn Output is proportionally provided to the input between these setpoints SCPTsetpoint 0 SCPTsetpoint 1 SCPTsetpoint 1 nviCVIn Same as nviCVIn SCPTsetpoint 0 nvoCVOut Same as nvoCVOut SCPTs...

Page 11: ...iables Configuration Properties Extension discrete output Y0 Y2 Y4 Y6 Y8 YA YC YE Output nviDOEX1 status Y1 Y3 Y5 Y7 Y9 YB YD YF Output nviDOEX2 status nv 4 nv 11 nviDOEX1 SNVT_switch nv 12 nv 19 nviD...

Page 12: ...n or off Y1 Y3 Y5 Y7 Y9 YB YD YF of the extension module depending upon this input 100 0 1 ON Other OFF Configuration Properties CONFIGURATION PROPERTY NETWORK VARIABLE TYPE Range Default EXPLANATIONS...

Page 13: ...8 XA XC XE X1 X3 X5 X7 X9 XB XD XF Normal Mode Status output at nvoDIEX1 Status output at nvoDIEX2 Combination Mode Refer to the table in the next page fbDIEX SCPTdirection nvoDIEX1 SCPTinvrtOut nvoDI...

Page 14: ...X6 X8 XA XC XE X1 X3 X5 X7 X9 XB XD XF nvoDIEX1 nvoDIEX2 OFF OFF 0 0 0 OFF Invalid ON OFF 100 0 1 ON Invalid OFF ON 0 0 0 OFF 0 0 0 OFF ON ON 100 0 1 ON 100 0 1 ON nvoDIEX2 SNVT_switch 0 0 0 100 0 1...

Reviews: