background image

R7L-YS2

5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN
Phone: +81(6)6659-8201  Fax: +81(6)6659-8510  E-mail: [email protected]

EM-7804-E  Rev.5  P. 3 / 14

TERMINAL CONNECTIONS

Connect the unit as in the diagram below.

 

EXTERNAL DIMENSIONS  unit: mm (inch)

2

3

4

1

5

10

7

8

9

6

4

5

6

7

1

2

3

30 (1.18)

[5 (.20)]

3 (.1

2)

5.5 (.22

)

7–M3 SCREW

TERMINALS

for L

ON

W

ORKS

, POWER

10–M3 SCREW 

TERMINALS

for OUTPUT

DIN RAIL

35mm wide

54 (2.13)

17 (.66)

6 (.24)

50 (1

.97

)

6 (.24)

18.5 (.73)

115 (4.53)

 

CONNECTION DIAGRAM

4

7

6

3

2

5

1

V (–)

U (+)

FG

NET2

NET2

NET1

NET1

OUTPUT 0

L

ON

W

ORKS

L

ON

W

ORKS

EXTENSION CONNECTOR

7

I0

2

COM0

9

4

I1

COM1

OUTPUT 1

WIRING INSTRUCTIONS

 

SCREW TERMINAL

Torque: 0.5 N·m

 

SOLDERLESS TERMINAL

Refer to the drawing below for recommended ring tongue 
terminal size.  Spade tongue type is also applicable.
Applicable wire size: 0.25 to 1.65 mm

2

 (AWG 22 to 16)

Recommended manufacturer: Japan Solderless Terminal 
MFG. Co., Ltd, Nichifu Co., Ltd

6 (.24) max

3.3 (.13) max

mm (inch)

COMMUNICATION CABLE CONNECTIONS

 HOST PC CONNECTION

HOST PC

L

ON

W

ORKS

R 7L

L

ON

W

ORKS

R 7L

L

ON

W

ORKS

Terminator

Summary of Contents for R7L-YS2

Page 1: ...co jp POINTS OF CAUTION POWER INPUT RATING OPERATIONAL RANGE Locate the power input rating marked on the product and confirm its operational range as indicated below 24V AC rating 24V 10 50 60 Hz appr...

Page 2: ...line Sending receiving of Net work Variables has stopped OFF Normal state INDICATOR LED Used to show network variable status assigned to fbLED ON LED ON OFF LED OFF SERVICE SWITCH Used to identify the...

Page 3: ...6 24 50 1 97 6 24 18 5 73 115 4 53 CONNECTION DIAGRAM 4 7 6 3 2 5 1 V U FG NET2 NET2 NET1 NET1 OUTPUT 0 LONWORKS LONWORKS EXTENSION CONNECTOR 7 I0 2 COM0 9 4 I1 COM1 OUTPUT 1 WIRING INSTRUCTIONS SCRE...

Page 4: ...oemType SCPTserialNumber Extension module setting Maximum sending time per fb Minimum sending time per fb Set Tag No name Indicate Model No and Version Indicate Serial No NodeObject Network Variables...

Page 5: ...0 0 Maximum time interval to send network variables per fb Power supply must be reset when this configuration prop erty is changed Network variables are sent out in the specified intervals even when...

Page 6: ...NTOut Set the maximum count Set the value when fbCNT is reset fbCNT SCPTdirection nviCNTIn SCPTinvrtOut nviCNTCtrl SCPTpwrUpState nvoCNTOut SCPTnvType SCPTmaxRnge SCPTsetpoint Network Variables Config...

Page 7: ...Count always reset to 0 Bit 5 8 through 15 Invalid Minimum input pulse width 500 ms for nviCNTIn 50 ms for the input terminals DO NOT connect a network variable to nviCNTIn when one of the input term...

Page 8: ...the current at Output 0 and 1 Configuration Properties CONFIGURATION PROPERTY NETWORK VARIABLE TYPE Range Default EXPLANATIONS SCPTsetpoint 0 nviYSVal SNVT_lev_percent 15 000 115 000 0 0 nviYSVal low...

Page 9: ...tpoints Network variable type 0 and 100 setpoints nviCVIn SCPTnumDigits SCPTnvType SCPTsetpoint nvoCVOut SCPTnvType SCPTsetpoint Network Variables Configuration Properties nv 62 nv 63 nv 64 nv 65 Netw...

Page 10: ...int 1 nviCVIn Output is proportionally provided to the input between these setpoints SCPTsetpoint 0 SCPTsetpoint 1 SCPTsetpoint 1 nviCVIn Same as nviCVIn SCPTsetpoint 0 nvoCVOut Same as nvoCVOut SCPTs...

Page 11: ...iables Configuration Properties Extension discrete output Y0 Y2 Y4 Y6 Y8 YA YC YE Output nviDOEX1 status Y1 Y3 Y5 Y7 Y9 YB YD YF Output nviDOEX2 status nv 4 nv 11 nviDOEX1 SNVT_switch nv 12 nv 19 nviD...

Page 12: ...n or off Y1 Y3 Y5 Y7 Y9 YB YD YF of the extension module depending upon this input 100 0 1 ON Other OFF Configuration Properties CONFIGURATION PROPERTY NETWORK VARIABLE TYPE Range Default EXPLANATIONS...

Page 13: ...8 XA XC XE X1 X3 X5 X7 X9 XB XD XF Normal Mode Status output at nvoDIEX1 Status output at nvoDIEX2 Combination Mode Refer to the table in the next page fbDIEX SCPTdirection nvoDIEX1 SCPTinvrtOut nvoDI...

Page 14: ...X6 X8 XA XC XE X1 X3 X5 X7 X9 XB XD XF nvoDIEX1 nvoDIEX2 OFF OFF 0 0 0 OFF Invalid ON OFF 100 0 1 ON Invalid OFF ON 0 0 0 OFF 0 0 0 OFF ON ON 100 0 1 ON 100 0 1 ON nvoDIEX2 SNVT_switch 0 0 0 100 0 1...

Reviews: