R7G4HH-A-YVF4

5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN
Phone: +81(6)6659-8201  Fax: +81(6)6659-8510  E-mail: [email protected]

EM-7777-F  Rev.2  P. 6 / 9

TERMINAL CONNECTIONS

Connect the unit as in the diagram below.

 

EXTERNAL DIMENSIONS  unit: mm (inch)

130 (5.12)

140 (5.51)

152 (5.98)

4(.16)

50 (1.97)

5(.2) 4(.16)

4.5 (.18) dia

6

18-M3 Output 
terminal screws 

4

5

6

7

1

2

3

6

7-M3 power supply
terminal screws

10 11 12 13

2

3

4

1

15 16 17 18

7

8

9

6

14

5

4(.16)

57 (2.24)

55 (2.17)

DIN rail

(35mm wide)

4 (.16) deep

Summary of Contents for R7G4HH-A-YVF4

Page 1: ...to ensure the CE conform ity POWER INPUT RATING OPERATIONAL RANGE Locate the power input rating marked on the product and confirm its operational range as indicated below 24V DC rating 24V DC 10 appr...

Page 2: ...ormal Turns off when the internal power is abnormal RUN Green Turns on when the refresh data is received normally Turns off when no communication or communication error ERR Red Turns off when output c...

Page 3: ...ed to the output reset value Transfer Rate SW1 8 SW1 8 TRANSFER RATE OFF 12Mbps ON 6Mbps Note Be sure to set unused SW1 1 and 1 2 to OFF TERMINATING RESISTOR To use the terminating resistor turn the s...

Page 4: ...f duplex communication 12345678 12345678 1 NC 2 NC 3 NC 4 TR 5 TR 6 NC 7 NC 8 SLD Unused Unused Unused Network Network Unused Unused Shield Full duplex communication Communication connector pin assign...

Page 5: ...move the upper hook of the unit from the DIN rail 1 2 3 DIN RAIL MOUNTING RIGHT ANGLE Mounting 1 Insert the longer DIN rail mounter slider until it clicks twice as shown below 1 2 Set the upper hook a...

Page 6: ...F Rev 2 P 6 9 TERMINAL CONNECTIONS Connect the unit as in the diagram below EXTERNAL DIMENSIONS unit mm inch 130 5 12 140 5 51 152 5 98 4 16 50 1 97 5 2 4 16 4 5 18 dia 6 18 M3 Output terminal screws...

Page 7: ...3 17 8 9 VH3 VL3 COM3 13 VH1 VL1 COM1 4 5 15 VH2 VL2 COM2 6 7 4 5 3 6 PAIR WIRING Ethernet cable pin assignment 4 5 6 7 8 2 3 NC TXD TR 1 NC RXD NC RXD NC NC SLD TXD TR 4 5 6 7 8 2 3 NC 1 NC NC SLD 6...

Page 8: ...ELD Full duplex communication Half duplex communication MASTER CONNECTION Terminating Resistor MOUNTING REQUIREMENTS unit mm inch 140 5 51 2 M4 WIRING INSTRUCTIONS TORQUE Wiring screw for separable te...

Page 9: ...gurable with the configurator software model R7CFG Refer to the software manual for details ADD n ADD n ADD n 2 ADD n 1 ADD n 4 ADD n 2 ADD n 6 ADD n 3 Data is represented in 16 bit binary Negative va...