EM-7777-F  Rev.2  P. 2 / 9

COMPONENT IDENTIFICATION

Status Indicator LED

Station Address Setting 

Rotary SW

Output Terminals

Power Supply Terminals

PC Configurator Jack

Operating Mode Setting 

DIP SW (SW1)

Terminating Resistor SW (SW2)

RJ-45 Modular Jack for HLS

■ 

FRONT VIEW

■ 

TOP VIEW

4

5

6

7

1

2

3

10 11 12 13

2

3

4

1

15 16 17 18

7

8

9

6

14

5

HLS1

HLS2

PWR

SA1

×10

SA2

×1

ERR

RUN

 

STATUS INDICATOR LED

ID

COLOR

FUNCTION

PWR

Green

Turns on when the internal power is 
normal.
Turns off when the internal power is 
abnormal.

RUN

Green

Turns on when the refresh data is 
received normally.
Turns off when no communication or 
communication error.

ERR

Red

Turns off when output circuit is normal.
Turns on when output value is not 
greater than -15% or not lower than 
115%.

 

STATION ADDRESS

The left switch determines the sixteenths place digit, while 
the right switch does the ones place digit of the address.  
The data allocation is 4.

• Full-duplex communication

   Setting “n” with the rotary switches, the addresses are n, 

n+2, n+4 and n+6.  (Range: 01H to 39H)

• Half-duplex communication

   Four (4) addresses are assigned from the one set with the 

rotary switch.  (Range: 01H to 3CH)

Station Address Setting (LSD)

Station Address Setting (MSD)

89A

BC

D

EF

0123

45

67

89A

BC

D

EF

0123

45

67

Summary of Contents for R7G4HH-A-YVF4

Page 1: ...to ensure the CE conform ity POWER INPUT RATING OPERATIONAL RANGE Locate the power input rating marked on the product and confirm its operational range as indicated below 24V DC rating 24V DC 10 appr...

Page 2: ...ormal Turns off when the internal power is abnormal RUN Green Turns on when the refresh data is received normally Turns off when no communication or communication error ERR Red Turns off when output c...

Page 3: ...ed to the output reset value Transfer Rate SW1 8 SW1 8 TRANSFER RATE OFF 12Mbps ON 6Mbps Note Be sure to set unused SW1 1 and 1 2 to OFF TERMINATING RESISTOR To use the terminating resistor turn the s...

Page 4: ...f duplex communication 12345678 12345678 1 NC 2 NC 3 NC 4 TR 5 TR 6 NC 7 NC 8 SLD Unused Unused Unused Network Network Unused Unused Shield Full duplex communication Communication connector pin assign...

Page 5: ...move the upper hook of the unit from the DIN rail 1 2 3 DIN RAIL MOUNTING RIGHT ANGLE Mounting 1 Insert the longer DIN rail mounter slider until it clicks twice as shown below 1 2 Set the upper hook a...

Page 6: ...F Rev 2 P 6 9 TERMINAL CONNECTIONS Connect the unit as in the diagram below EXTERNAL DIMENSIONS unit mm inch 130 5 12 140 5 51 152 5 98 4 16 50 1 97 5 2 4 16 4 5 18 dia 6 18 M3 Output terminal screws...

Page 7: ...3 17 8 9 VH3 VL3 COM3 13 VH1 VL1 COM1 4 5 15 VH2 VL2 COM2 6 7 4 5 3 6 PAIR WIRING Ethernet cable pin assignment 4 5 6 7 8 2 3 NC TXD TR 1 NC RXD NC RXD NC NC SLD TXD TR 4 5 6 7 8 2 3 NC 1 NC NC SLD 6...

Page 8: ...ELD Full duplex communication Half duplex communication MASTER CONNECTION Terminating Resistor MOUNTING REQUIREMENTS unit mm inch 140 5 51 2 M4 WIRING INSTRUCTIONS TORQUE Wiring screw for separable te...