background image

R7D-YS2

EM-7802-E  Rev.6  P. 6 / 10

 

STATUS

Bit 0 to 7:  Analog output module shows ‘0’ at the same address.
Bit 8 to 10:  Shows the power supply status.

0

15

Remains “0”
Remains “0”
Remains “0”

Unused

Remains “0”
Remains “0”
Remains “0”
Remains “0”
Remains “0”

     :

     :

     :

Network power supply
Unused

Unused

Extension module external power supply

Power supply
     0 : Normal     1 : Error

TRANSMISSION DATA DESCRIPTIONS

 

BASIC MODULE

Transmitted data (word) depends upon the modules types.

MODEL

OUTPUT DATA

*

1

INPUT DATA

*

2

(R7D to Master)

(Master to R7D)

R7D-YS2x

0

2

 

EXTENSION MODULE

Transmitted data (word) for the extension module is added.

MODEL

OUTPUT DATA

*

1

INPUT DATA

*

2

(R7D to Master)

(Master to R7D)

R7D-EAx

1

0

R7D-ECx

0

1

 

STATUS

Status signal can be included in the transmission data 
when the setting is enabled using the PC Configurator soft-
ware (model: R7CON).  For details, refer to “STATUS in I/O 
DATA DESCRIPTIONS”.

STATUS

OUTPUT DATA

*

1

INPUT DATA

*

2

(R7D to Master)

(Master to R7D)

Enabled

1

0

Disabled

0

0

*1. Output Data means those sent to the master.
*2. Input Data means those received from the master.

WIRING INSTRUCTIONS

 

SCREW TERMINAL (Output)

Torque: 0.5 N·m

• SOLDERLESS TERMINAL

Refer to the drawing below for recommended ring tongue 
terminal size.  Spade tongue type is also applicable.
Applicable wire size: 0.25 to 1.65 mm

2

 (AWG 22 to 16)

Recommended manufacturer: Japan Solderless Terminal 
MFG. Co., Ltd, Nichifu Co., Ltd

6 (.24) max

3.3 (.13) max

mm (inch)

 

EURO TYPE CONNECTOR TERMINAL (DeviceNet)

Applicable wire size: 0.2 – 2.5 mm

2

Stripped length: 7 mm

056 222 38 18

[email protected]

www.sentronic.com

SENTRONIC

AG

Summary of Contents for R7D-YS2/UL

Page 1: ...p to 2000 meters This equipment must be mounted inside a suitable fire enclosure This equipment is to be supplied by a Class 2 power sup ply CONFORMITY WITH EU DIRECTIVES The equipment must be mounted...

Page 2: ...ch 5 4 3 2 1 0 9 8 7 6 Baud Rate Setting 0 125 kbps factory setting 1 250 kbps 2 500 kbps 3 thr 9 Auto tracking The R7D communicates in the baud rate setting detected at the startup with the switch se...

Page 3: ...out 0 0 3276 7 sec 1 0 sec Status Data ON Disable OFF Enable OFF Enable Serial ID English one byte characters within 8 characters CHANNEL INDIVIDUAL SETTING PARAMETER SETTING RANGE DEFAULT SETTING Zer...

Page 4: ...9 6 2 3 4 1 5 30 1 18 5 20 3 12 3 12 5 5 22 DIN RAIL 35mm wide 54 2 13 17 66 50 1 97 18 5 73 115 4 53 10 M3 SCREW TERMINALS for OUTPUT 6 24 TERMINAL BLOCK for DeviceNet POWER CONNECTION DIAGRAM 7 I0 2...

Page 5: ...0 Begin 0 CH0 CH1 1 2 Output Data Example 2 Analog Output Module R7D EC16x with Status Analog Output Module R7D EC16x Input Data I O DATA DESCRIPTIONS 0 15 16 bit binary data Negative values represent...

Page 6: ...TUS Status signal can be included in the transmission data when the setting is enabled using the PC Configurator soft ware model R7CON For details refer to STATUS in I O DATA DESCRIPTIONS STATUS OUTPU...

Page 7: ...a thick cable to maintain low imped ance at high frequency Use shielded cables for the signals taken out of the control panel Choose a thick and short cable to ground the FG terminal of the R7D module...

Page 8: ...d the panel cover with an earth strap grounding may be strengthened and EMC may be improved Ground the control panel at low impedance using e g braided wires Keep the opening for ventilation as small...

Page 9: ...cautions are illustrated in the next page Keep cables as short as possible It prevents noise emissions from the cables and noise overlapping to the cables Attach a ferrite core to reduce noise impact...

Page 10: ...pplicable when wiring the R7D Series To external apparatus Keep the cable as short as possible To external apparatus Shielded Cable Earth Clamp Remove a part of the shielded cable cover and ground it...

Reviews: