46
M3LU2 OPERATING MANUAL EM-2653-B Rev.0
12.3 MODEL NUMBERING
Code number:
M3LU2–[1]/[2][3]
INPUT – Field-selectable
DC Current & Voltage
Current: 0 – 20 mA DC
Millivolt: -1000 – +1000 mV DC
Voltage: -10 – +10 V DC
Thermocouple
(PR), K, E, J, T, B, R, S, C (WRe 5-26), N, U, L, P (Platinel II)
RTD
Pt 100, Pt 200, Pt 300, Pt 400, Pt 500, Pt 1000, Ni 100, Ni 120, Ni 508.4 Ω, Ni-Fe 604, Cu 10 @25°C,
Pt 50 Ω, JPt 100
Potentiometer
Total resistance 80 – 4000 Ω
Resistance
0 – 4000 Ω
OUTPUT – Field-selectable
Current
0 – 20 mA DC
Voltage
-2.5 – +2.5 V DC
-10 – +10 V DC
[1] POWER INPUT
AC Power
M2: 100 – 240 V AC (Operational voltage range 85 – 264 V, 47 – 66 Hz)
DC Power
R4: 10 – 32 V DC (Operational voltage range 9 – 36 V, ripple 10% p-p max.)
[2] CONFIGURATION OPTIONs
A: PC and field configurable
B: Field configurable
[3] OPTIONs
blank: none
/Q: With options (specify the specification)
sPECIFICATIONs OF OPTION: Q
COATING (For the detail, refer to M-System’s web site.)
/C01: Silicone coating
/C02: Polyurethane coating
/C03: Rubber coating