[90] Display setting

Set display setting in measuring mode.  Display is di-
vided, indicating item can be set for each upper and lower.  
Pressing Set button once is setting for upper, pressing again 
for lower, pressing once more for setting determined.

Upper

SETTING VALUE

DESCRIPTION

INITIAL VALUE

INPUT

Input engineering unit value

I N P U T 
(engineering 
value)

INPUT (Scaling)

*1

Input scaling

PERCENT

Percent value

*3

OUTPUT

Output engineering unit value

OUTPUT (Scaling)

*2

Output scaling

*1.  Display at measuring mode is INP (Scaling).
*2.  Display at measuring mode is OUT (Scaling).
*3.  Input percent value.

Lower

SETTING VALUE

DESCRIPTION

INITIAL VALUE

INPUT

Input engineering unit value

PERCENT 

(percent value)

*3

INPUT (Scaling)

*1

Input scaling

PERCENT

Percent value

*3

OUTPUT

Output engineering unit value

OUTPUT (Scaling)

*2

Output scaling

None

No display

*1.  Display at measuring mode is INP (Scaling).
*2.  Display at measuring mode is OUT (Scaling).
*3.  Input percent value.

[91] Brightness

Adjust brightness of display.  It is available to set the range 
between 1 (darkest) – 4 (brightest).
Initial value: 4

[92] Display timeout

Set the time to off the display when there is no operation 
within a certain time.
It is available to set the range between 0 – 60 minutes.
Set ‘0’ to display ‘always on’.
When error is occured at display off, the display returns 
from off.
Initial value: 10

[93] Reset all settings

Return settings to initial value.

SETTING VALUE

DESCRIPTION

OFF

Not initialized.

RESET

Initialize all settings.

*1

*1.  When setting value is initialized, each parameters cur-

rently set are over written by initial value.  ‘COMPLETE’ is 
indicated when initializing setting value is completed.  No-
tice that it does not return to the setting value, which is 
specified by the option Ex-factory setting (/SET).  Configure 
initialized value again with DIP switch with power off for 
output setting.

[94] Version indication

Indicate firmware version.

[01] Lockout setting

Set Lock / Unlock of lockout setting.

SETTING VALUE DESCRIPTION

INITIAL VALUE

Lock

Lockout setting enable

Lock

Unlock

Lockout setting disable

Even when setting is ‘Lock’, it is available to move on to 
each setting mode and confirm the setting value of each 
setting parameter. In each setting parameter display, when 
‘Lock’, ‘DATA (Locked)’ is indicated, when ‘Unlock’, ‘DATA’ 
is indicated.

Summary of Contents for M2EXS

Page 1: ...f this unit when it is integrated in a panel system The user may have to review the CE requirements in regard to the whole system and employ additional protective measures to ensure the CE conform ity...

Page 2: ...ving the socket push down the DIN rail adaptor utilizing a minus screwdriver and pull WALL MOUNTING Refer to the drawings in the shown below TERMINAL CONNECTIONS Connect the unit as in the diagram bel...

Page 3: ...ing changeable state used to enter save the setting value Used to move on through digits of setting value for input output scaling at setting changeable state Up Button Used to shift through setting p...

Page 4: ...tting of the Advanced mode for settings DISPLAY IN EACH SETTING MODE For each setting current values of setting parameter ITEM number and setting value are indicated During setting Setting is indicate...

Page 5: ...RT POWER ON Measuring Mode Hold down Mode Button for 2 seconds Hold down Mode Button for 2 seconds Basic Setting Mode Option Mode Advanced Mode Hold down Mode Button for 2 seconds Hold down Mode Butto...

Page 6: ...ing value to set value Keeping pressing Down button enables to decrease the value continuously Operation of input setting parameter 06 Angle offset is set by teach The present input value is displayed...

Page 7: ...ds Set Set Set Set Set Set Set Set Set Set Set Set Set Set Set Set Set Set Set Set Set Set Up Down Up Down Up Down Up Down Up Down Up Down Up Down Up Down Up Down Up Down Up Down Up Down Up Down Up Do...

Page 8: ...input scaling 99999 999999 100 00 16 Input decimal point No decimal point The number of decimal places 1 5 2 places of decimals 17 Output range 0 20mA 5 5V 10 10V 0 20mA 18 0 output setting 0 000 19 0...

Page 9: ...the unit SETTING VALUE DESCRIPTION INITIAL VALUE 0 20 mA Output 0 20 mA DC 0 20 mA 5 5 V Output 5 5 V DC 10 10 V Output 10 10 V DC When output range is changed turn the power off and then set the outp...

Page 10: ...ase it by pressing Up and Down button Press and hold them enables to change value continuously 1 Pressing and holding Mode button more than 2 seconds or turning off the power enable to exit loop test...

Page 11: ...ble unit Set Set Hold down Mode button for 4 seconds Hold down Mode button for 2 seconds Set Set Set Set Set Set Set Set Set Set Set Up Down Up Down Up Down Up Down Up Down Up Down 1 1 0 30 5 000 5 00...

Page 12: ...to user s unit setting display A unit can be created by using any characters Up to 13 characters available 1 Up and Down button enables to move on selected characters Set button enables to select a ch...

Page 13: ...wn Mode button for 6 seconds Hold down Mode button for 2 seconds Set Set Set Set Set Set Set Set Up Down Up Down Up Down Up Down Up Down Up Down 1 1 4 0 1 60 OFF RESET Lock Unlock Advanced Mode Parame...

Page 14: ...Adjust brightness of display It is available to set the range between 1 darkest 4 brightest Initial value 4 92 Display timeout Set the time to off the display when there is no operation within a certa...

Page 15: ...de button for 8 seconds Hold down Mode button for 2 seconds Set Set Set Set Set Set Set Set Set Set Set Set Set Up Down Up Down Up Down Up Down Up Down Up Down Up Down Up Down Disable Enable 2 32 5 00...

Page 16: ...een 5 to 105 for both X and Y For X it is required to set in ascending order from X001 Be sure that if it is set with other than ascending order cor rect conversion is not carried out Initial value X0...

Page 17: ...rror occurs only high priority error is displayed Order of priority is EEPROM ERROR OVER RANGE SCALING ERROR in descending order ERROR MESSAGES DISPLAY SETTING INPUT ENGINEERING UNIT VALUE INPUT SCALI...

Page 18: ...ed in the users manual of the M2ECFG configurator software Or follow the procedure shown below INPUT FINE ADJUSTMENT Set the input signal to 0 and adjust the input to 0 by 06 Angle offset OUTPUT FINE...

Reviews: