LC / LCS
P. 3 / 4
EM-1355 Rev.3
■
DIMENSIONS mm (inch)
5
6
7
8
2
1
11
10
80 (3.15)
50 (1.97)
107 (4.21)
136 (5.35)
[3.3 (.13)]
80 (3.15)
20
(.79)
35.4 (1.39)
40 (1.57)
50 (1.97)
7.8 (.31)
CLAMP
(top & bottom)
DIN RAIL
35mm wide
2–4.5 (.18) dia.
MTG HOLE
25 (.98) deep
11–M3.5
SCREW
•When mounting, no extra space is needed between units.
3
9
4
■
CONNECTION DIAGRAM
7
8
+
–
10
3
9
6
11
+
–
STRAIN
GAUGE
2
1
INPUT
EXC.
+
–
OUTPUT
U(+)
V(–)
POWER
INSTALLATION
Detach the yellow clamps located at the top and bottom of the
unit for separating the body from the base socket.
■
DIN RAIL MOUNTING
Set the base socket so that its
DIN rail adaptor is at the bot-
tom. Position the upper hook at
the rear side of base socket on
the DIN rail and push in the
lower. When removing the
socket, push down the DIN rail
adaptor utilizing a minus screw-
driver and pull.
■
WALL MOUNTING
Refer to the drawings in the
following page.
Clamp
(top & bottom)
DIN Rail
35mm wide
Spring Loaded
DIN Rail Adaptor
Shape and size of the base socket
are slightly different with various
socket types.
TERMINAL CONNECTIONS