background image

AS4V

5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN
Phone: +81(6)6659-8201 Fax: 

+81(6)6659-8510  E-mail: [email protected]

EM-1609  Rev.15  P. 4 / 5

ITEM

MDF.

CODE

DATA

CONTENTS

DEFAULT SETTING

23
24
25
26

2
2
2
2

1 – 9999
1 – 9999
1 – 9999
1 – 9999

L1 hysteresis (deadband) in engineering unit
L2 hysteresis (deadband) in engineering unit
L3 hysteresis (deadband) in engineering unit *

2

L4 hysteresis (deadband) in engineering unit *

2

1.0
1.0
1.0
1.0

27

2

S1: -1.00 – 1.00
S2: -10.0 – 10.0 

Z1: 0.0 – 50.0

    0% input voltage/current (ITEM 27 < ITEM 28)

S1: -1.00 V, S2: -10.0 V, Z1: 4.0 mA

28

2

S1: -1.00 – 1.00
S2: -10.0 – 10.0 

Z1: 0.0 – 50.0 

100% input voltage/current (ITEM 27 < ITEM 28)

S1: 1.00 V, S2: 10.0 V, Z1: 20.0 mA

29

2

0, 1

Latching control      (0: Disabled, 1: Enabled)
Selecting “0” resets latching relays.  Turning power supply off also 
resets them.

0

30

----

0000 – 1111

Alarm indication     (0: OFF, 1: ON)
The MSD indicates the L1, while the LSD indicates the L4.

----

*1. Selectable within the display scaling range
*2. Quad alarm trip type only
*3. Of the range set in ITEM 05, 06.  ITEM 07 < ITEM 08.
*4. OFF when power is on.  After power is turned on, pressing any key enables to turn on continuously.

CONNECTIONS

 

EXTERNAL DIMENSIONS  unit: mm (inch)

• 

W

hen mounting, no extra space is needed between units

.

5

6

7

8

2

1

11

10

80 (3.1

5)

40 (1

.57)

50 (1

.97)

7

.8 (.31)

2

4.5 (.18) dia.

MTG HOL

E

25 (.98) deep

11

M3.5

SCREW

3

9

4

For wiring connection, refer to “TERMINAL CONNECTIONS” and wire correctly.
Fire, electric shock and failure cause if wire are incorrectly connected.

80 (3.1

5)

50 (1.97)

103 (4.06)

132 (5.20)

20 (.79)

[3.3 (.13)]

35.4 (1

.39)

CLAMP

(top & bottom)

DIN RAIL

35mm wide

 

TERMINAL ASSIGNMENTS

7

8

2

1

11

10

3

9

4

12 (.47)

INPUT RESISTOR

(model: REM)

5

6

Input shunt resistor attached 
for current input.

TERMINAL CONNECTIONS

Connect the unit as in the diagram below or refer to the connection diagram on top of the unit.

U(+)

V(–)

POWER

7

8

+

*

INPUT

5

R

6

Input shunt resistor attached for current input.

10

11

9

2

3

1

L2 OUTPUT

L1 OUTPUT

N.C.

N.O.

COM

N.C.

N.O.

COM

n SPDT RELAY

U(+)

V(–)

POWER

7

8

+

*

INPUT

5

R

6

Input shunt resistor attached for current input.

10

11

9

2

3

1

L4 OUTPUT

L1 OUTPUT

COM

L3 OUTPUT

L2 OUTPUT

COM

n N.O. RELAY

n N.C. RELAY

10

11

9

2

3

1

L4 OUTPUT

L1 OUTPUT

COM

L3 OUTPUT

L2 OUTPUT

COM

U(+)

V(–)

POWER

7

8

+

*

INPUT

5

R

6

Input shunt resistor attached for current input.

10

11

9

2

3

1

L2 OUTPUT

L1 OUTPUT

N.C.

N.O.

COM

N.C.

N.O.

COM

n SPDT RELAY

U(+)

V(–)

POWER

7

8

+

*

INPUT

5

R

6

Input shunt resistor attached for current input.

10

11

9

2

3

1

L4 OUTPUT

L1 OUTPUT

COM

L3 OUTPUT

L2 OUTPUT

COM

n N.O. RELAY

n N.C. RELAY

10

11

9

2

3

1

L4 OUTPUT

L1 OUTPUT

COM

L3 OUTPUT

L2 OUTPUT

COM

Reviews: