• The unit is designed to function as soon as power is sup-

plied, however, a warm up for 10 minutes is required for 
satisfying complete performance described in the data 
sheet.

COMPONENT IDENTIFICATION

50

40

30

20

10

0

10

20

30

40

50

m

3

/h

%

mA

100 SET

H

S

P

Z

L

90

80

70

60

50

40

30

20

10

0

M

Brackets

Body

A

Scale Plate

Pull up the part ‘A’ when replacing the scale plate.

INSTALLATION

 

PANEL CUTOUT  unit: mm

138

+1 –0

31.5

Note 1:  Observe at the minimum of 3 cm above and below the units 
              for heat dissipation.
Note 2:  No bezel is needed when the panel is cut according to the 
              above drawings.

Panel thickness: 1.6 – 8.0 mm

■ 

SINGLE MOUNTING 

    (Conform to degree of protection IP65)

138

+1 –0

L

Panel thickness: 1.6 – 8.0 mm

 
L = {31.5 + 36 × (N – 1)}
(N : number of units)

+1

–0

■ 

CLUSTERED MOUNTING 

    (Not conform to degree of protection IP65)

+1

–0

61.5 min.

 

USING BEZELS

Bezels are used when the unit needs to be adapted to an ex-
isting panel cutout.  It is not required when the panel cutout 
size is as specified in the unit’s data sheet (31.5 × 138 mm).
Three types of bezels are selectable when ordering.
  Standard type:   Fits into M-System’s 48 Series’ panel   

cutout (38 × 139.5 mm)

  Option /D type:  Fits into DIN panel cutout
     

 

 

 

(33 × 138 mm)

  Option /F type:  Fits into Fuji Electric PAJ, PAK, PBA,
         

 

 

etc, panel cutout (44 × 138 mm)

Slide the top and bottom parts of the bezel into the back of 
the front cover as shown below.

Bezel

When multiple units are to be clustered side by side, insert 
one bezel between two units as shown below.

• When mounting two or more indicators side by side:

 

HOW TO MOUNT THE UNIT ON A PANEL

1) Insert the unit into the panel cutout.  The watertight 

packing must be in place to hold the unit.  Do not remove 

it even when the protection is not required.

  The IP65 front cover protection is effective only with sin-

gle mounting, with the designated cutout size (31.5 ×138 

mm).

Panel

Watertight Packing

Summary of Contents for 48NDV

Page 1: ...system The user may have to review the CE or UKCA requirements in regard to the whole system and employ additional protective measures to ensure the CE or UKCA conformity In order to enable the operator to turn off the power in put immediately install a switch or a circuit breaker ac cording to the relevant requirements in IEC 60947 2 and properly indicate it POWER INPUT RATING OPERATIONAL RANGE L...

Page 2: ...STERED MOUNTING Not conform to degree of protection IP65 1 0 61 5 min USING BEZELS Bezels are used when the unit needs to be adapted to an ex isting panel cutout It is not required when the panel cutout size is as specified in the unit s data sheet 31 5 138 mm Three types of bezels are selectable when ordering Standard type Fits into M System s 48 Series panel cutout 38 139 5 mm Option D type Fits...

Page 3: ...nd below the unit for ventilation Bracket TERMINAL CONNECTIONS Connect the unit as in the diagram below or refer to the connection diagram on the side of the unit EXTERNAL DIMENSIONS unit mm inch 75 2 95 103 4 06 10 39 18 71 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 16 M3 SCREW TERMINALS 2 M3 SCREWS 144 5 67 137 5 5 41 4 1 16 36 1 42 31 1 22 100 3 94 Rounded corners for the option D OPTION D BEZEL 3 ...

Page 4: ...c PAJ PAK PBA 44 138 mm etc STANDARD BEZEL 2 10 4 41 7 5 30 3 9 15 136 5 5 37 144 5 67 11 4 45 7 5 30 4 9 19 136 5 5 37 144 5 67 8 5 33 10 4 41 7 5 30 136 5 5 37 144 5 67 OPTION F BEZEL 4 CONNECTION DIAGRAM ALARM OUTPUT CODE 4 4 points ALARM OUTPUT CODE 2 2 points ALARM OUTPUT CODE 0 None 1 2 12 13 14 INPUT 15 16 1 2 12 13 14 15 16 INPUT LLa 11 La LLb Lc LLc 7 8 9 8 9 10 HHa 7 Hc HHc HHb Ha HH OUT...

Page 5: ...Settings Mode Setting Selector Setting DOWN Button Switcing Detailed Settings Digital Indicator Setpoint 2 Value Setpoint 1 Value PV Indicator Note Setpoint 1 or 2 provided only for the multi color bar type ALARM OUTPUT CODE 0 None SET ENTER Button H Setpoint Adj Alarm Function Span Adj Setting Decimal Point Position Moving Average Brightness Adj Zero Adj Setting L Setpoint Adj Alarm Function Sett...

Page 6: ...Delay for L Setpoint Increase Decrease Complete Digital Indicator SET L LL M Press at once ON Time Delay for LL Setpoint Increase Decrease Complete Digital Indicator SET LL Z M Press at once Zero Adjustment Digital Indicator Bargraph Z SET Z M Increase Decrease Zero Adjustment Digital Indicator Only Complete Z ON LED OFF SPAN ADJUSTMENT Apply 100 input signal before adjustment All alarm setpoints ...

Page 7: ...itched to continuous ON state 4 Press UP or DOWN buttons until the bargraph shows 100 and the digital indicator comes to a desired value and press SET DIGITAL INDICATOR SPAN ADJUSTMENT 1 Hold down M for 3 seconds and push M to choose S 2 Press UP or DOWN buttons until the digital indicator comes to a desired value and press SET DECIMAL POINT POSITION 1 Hold down M for 3 seconds and push M to choos...

Page 8: ...ibration adjust the output as explained in the following HOW TO CALIBRATE THE OUTPUT INDICATION Use a signal source and measuring instruments of sufficient accuracy level Turn the power supply on and warm up for more than 10 minutes 1 ZERO Apply 0 input and adjust the bargraph and digital indicator to 0 following the each procedure ex plained in ADJUSTMENT PROCEDURE 2 SPAN Apply 100 input and adju...

Reviews: