background image

48NAVA

5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN
Phone: +81(6)6659-8201  Fax: +81(6)6659-8510  E-mail: [email protected]

EM-9442  Rev.8  P. 6 / 9

FRONT PANEL CONFIGURATION

 ALARM OUTPUT CODE 2: 2 points

 ALARM OUTPUT CODE 4: 4 points

• Bar Color Patterns

Pattern 1 (Bar LED color code 1)

orange

orange

green

orange

Input < L

L < Input < H

H < Input

green

red

H

L

Pattern 2 (Bar LED color code 2)

orange

green

green

red

red

red

H

L

50

40

30

20

10

0

-10

-20

-30

-40

-50

m

3

/h

%

100 SET

H

S

Z

L

90

80

70

60

50

40

30

20

10

0

SET (ENTER) Button

H Setpoint Adj. & Trip Indicator (red)
Span Adj. (amber)
Power Saving Mode Indicator (amber)
Zero Adj. (amber)
L Setpoint Adj. & Trip Indicator (green)

UP Button

Mode Selector

DOWN Button

H Setpoint

L Setpoint

PV Indicator

M

50

40

30

20

10

0

-10

-20

-30

-40

-50

m

3

/h

%

100

SET

L

Z

S

90

80

70

60

50

40

30

20

10

0

H

M

• Vertical Mounting

• Horizontal Mounting

50

40

30

20

10

0

-10

-20

-30

-40

-50

m

3

/h

%

100 SET

H

S

Z

L

90

80

70

60

50

40

30

20

10

0

SET (ENTER) Button

HH Setpoint Adj. & Trip Indicator (red)
H Setpoint Adj. & Trip Indicator (red)
Span Adj. (amber)
Power Saving Mode Indicator (amber)
Zero Adj. (amber)
L Setpoint Adj. & Trip Indicator (green)
LL Setpoint Adj. & Trip Indicator (green)

UP Button

Mode Selector

DOWN Button

HH Setpoint

H Setpoint

L Setpoint

LL Setpoint

PV Indicator

HH

LL

M

50

40

30

20

10

0

-10

-20

-30

-40

-50

m

3

/h

%

100

SET

LL

L

Z

S

90

80

70

60

50

40

30

20

10

0

H

HH

M

• Vertical Mounting

• Horizontal Mounting

Summary of Contents for 48NAVA

Page 1: ...ironments such as panel con figurations connected devices connected wires may affect the protection level of this unit when it is integrated in a panel system The user may have to review the CE or UKC...

Page 2: ...NENT IDENTIFICATION 50 40 30 20 10 0 10 20 30 40 50 m3 h 100 SET H S Z L 90 80 70 60 50 40 30 20 10 0 M Brackets Body A Scale Plate Pull up the part A when replacing the scale plate INSTALLATION PANEL...

Page 3: ...mm Slide the top and bottom parts of the bezel into the back of the front cover as shown below Bezel When multiple units are to be clustered side by side insert one bezel between two units as shown be...

Page 4: ...13 14 15 16 16 M3 SCREW TERMINALS Rounded corners for the option D 2 M3 SCREWS 144 5 67 137 5 5 41 4 1 16 36 1 42 OPTION D BEZEL 3 1 Space required when replacing the scale plate 2 Used for the exist...

Page 5: ...UTPUT L OUTPUT ALARM OUTPUT CODE 2 2 points 5 6 INPUT 5 6 ALARM OUTPUT CODE 4 4 points 12 13 14 15 16 U V LLa 11 La LLb Lc LLc 8 9 10 HHa 7 Hc HHc HHb Ha HH OUTPUT H OUTPUT LL OUTPUT L OUTPUT POWER DC...

Page 6: ...r amber Zero Adj amber L Setpoint Adj Trip Indicator green UP Button Mode Selector DOWN Button H Setpoint L Setpoint PV Indicator M 50 40 30 20 10 0 10 20 30 40 50 m3 h 100 SET L Z S 90 80 70 60 50 40...

Page 7: ...inking Mode Selector 1 ZERO ADJUSTMENT Apply 0 input signal before adjustment Z SET Z M Zero Adjustment Complete LED OFF LED Blinking Mode Selector 1 S SET S M Span Adjustment Complete SPAN ADJUSTMENT...

Page 8: ...tput between 0 and 100 The bargraph shows the simulated output 4 Keep pressing SET button at least for 5 seconds to exit the simulated output mode Note Each setting sequence is complete only when SET...

Page 9: ...double speed 4 Press UP or DOWN buttons to show a desired value at the receiving instrument and press SET SIMULATED OUTPUT 1 Hold down DOWN for longer than 5 seconds to enter the simulation mode until...

Reviews: