MS-TestPro USER GUIDE
29
|
www.m4sol.com
MSolutions Cloud
The most recent firmware revision of the MS-TestPro enables Cloud connectivity of the test-
er to a centralised location. This system is perfect for companies with multiple MS-TestPro
units in the field, giving full view of the units in use, but also a centralised account to filter all
reports through to, in real-time.
To enable a Cloud account, please email: [email protected]
Please refer to the MS-TestPro Cloud User Guide document available to download on the
MSolutions website.
Device Power & PoH
The MS-TestPro MS-104B includes a li-ion battery cell giving the user maximum portability
when in use. The battery cell will allow for up to 4 hours of use between charges, It is rec-
ommended that the unit is left to drain the battery down to less than 20% (as indicated in
the top right of the screen) before fully charging the unit as this will prolong the battery life.
When installing the MS-TestPro to carry out Log Analysis over extended periods of time,
please connect the unit to the mains supply using the included power supply unit to avoid
the test being interrupted due to power failure.
The local MS-TestPro module supplies a 48V PoH (Power over HDBaseT) to the remote
module connected to the end of the CATx lnk. Connecting a 3rd party manufacturers TX or
RX that does not use PoH at the end of a link is likely to damage the equipment in use. The
same for 3rd party equipment sending other non-HDBaseT standard power schemes such
as PoC (Power over Cable), or PoW (Power over Wire) is likely to damage the test module.
The warranty of the MS-TestPro does not include damage to either TX, RX or the tester
caused by non-HDBaseT standard power schemes.