Caution!

• 

The lock has been designed for use in a temperature range from +10˚C to +50˚C and a non- 

  condensing humidity range from 30% to 80%.
•  It may only be cleaned with a moist cloth (do not use aggressive cleaning agents).
•  The lock may only be installed by qualified fitters.
•  The lock may not be lubricated.
•  Never open the lock housing. If it is necessary to disassemble the hardware, only do so in 
  accordance with the technical instructions. If you fail to do so, the lock may no longer function  
  properly and you will forfeit your right to warranty.

2

     CHARACTERISTICS

The motor lock can be mounted in all four mounting directions. The mounting dimensions are 
standard. The lock is delivered with metric (M6) mounting screws.
The electronics feature a 6-digit main code (in some cases it may be that the lock requires a 7-digit 
code) that can be changed by the user. With the main code user code(s) can be activated and deleted.   

After entering a valid code, a double signal sounds and the motor will retract the lock bolt. You can 
now open the door/bolt work. Closing the lock can either be done automatically by closing the door/
bolt work (Automatic Closing) or by pushing a random digit on the keypad (Push to Close). The default 
closing mode is Push to Close. The main code can change the closing mode to Automatic closing. To 
achieve “Automatic Closing” it is imperative that a door-/bolt work switch (NC=Normally Closed) is 
connected to the lock.
If the door is not opened within 5 seconds, the lock will automatically lock again in case “Automatic 
Closing” is active.
A signal will sound every 10 seconds as long as the lock is open in case “Push to Close” is active. 
Three long tones will sound when during  opening or closing the lock bolt is blocked. Entering the code 
again will close, respectively open the lock again. Remove the obstruction and retry.

Summary of Contents for Tantum Basic

Page 1: ...Made in The Netherlands Tantum Basic MLS Mounting instructions V02 EN...

Page 2: ...cedure will automatically abort You then have to start from the beginning After entering a valid code you will hear two audible tones An invalid entry will trigger a long tone If you accidentally ente...

Page 3: ...quires a 7 digit code that can be changed by the user With the main code user code s can be activated and deleted After entering a valid code a double signal sounds and the motor will retract the lock...

Page 4: ...the factory The standard dimensions are 30x45x1 5 LxWxH in mm The lock loses its certification if you retrofit the drill protection yourself Depending on the area of application construction and resis...

Page 5: ...ck bolt has to be limited to 1 kN E g by a preconceived breaking point Please contact your manufacturer if higher forces are needed Only use supplied screws to mount the lock In the LOCKED position th...

Page 6: ...th the fasten ing points of the boltwork 6 FUNCTIONAL TEST As with all locks from M LOCKS this unit has a unique feature for checking the electronics both that of the input unit and that of the lock F...

Page 7: ...ning Automatic Automatic Locking Automatic Push to Close Automatic Push to Close Blocking element Motor Motor Mounting dimensions Standard Standard Possible mounting positions 4 4 Tantum Basic Tantum...

Page 8: ...M LOCKS BV Vlijtstraat 40 7005 BN Doetinchem The Netherlands If you need some help please send an E mail to service m locks com We will be happy to help you...

Reviews: