background image

9

 

 

 

4

 

GENERAL RECOMMENDATIONS 

The device must be connected and tested before there is done the surround. To make sure the equipment 

is  working  optimally.  Do  not  place  flammable  materials  in  close  distance  of  the  fireplace  stove. 

Note:

  If  you 

leave the door open, a small piece of burning wood / carbon / may fall to the floor. 

Insulation materials:

 it is 

preferable  to  use  high  temperature  resistant  materials.  It  is  very  advantageous  position  for  connecting  of  the 
chimney  and  fireplace  in  the  direction  that  no  moisture  or  water  can  get  inside.  Moisture  and  water  can  cause 
that chamoflex swells and then bursts after the fire starts. 

 

4.1

 

MAINTANCE 

 

In  addition  to  regular  cleaning  of  glass,  must  be  your  chimney  at  least  once  a  year  sweep  to  insert 
optimal function. / It's not just a legal requirement, but it also makes sense for your own safety /.  

 

Refractory  bricks  /  babble  /  may  still  work  perfectly,  even  if  they  are  cracked.  However,  if  there  are 
missing pieces of bricks/material, bricks must be replaced in order to effectively protect the combustion 
chamber.  

 

To remove the ash residue use the ash holder /see Pic.12/ 

 
 
 
 
 
 
 
 
 
 

4.1.1

 

CLEANING GLASS 

 

Close the door / see Pic.4/ 

 

Unlock the door  /Pic.13/ move the door towards yourself /according the Pic.14/  

 

The glass can be now cleaned 

 

We recommend the cleaning product that you can use the  M-design „Bio – Clean“, which is available 
from your supplier. This is one of the few products that do not damage paint. 

 

If you use the fireplace often, it should be lightly brushed with a mechanism for keeping the door stabile 
silicone  oil.  Do  not  use  any  other  types  of  lubrication  or  oil.  This  lubrication  is  non-stick  base  and  is 
also available from dealers M-design. The mechanism may otherwise be dry and slider door locks. 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Obr.3a 

Obr.3d 

Pic. 12 

Pic.13 

Pic.14 

Summary of Contents for RD 750

Page 1: ...1 COLLECTION RD 750 1000 INSTRUCTION FOR INSTALLATION AND USE...

Page 2: ...S TYPE RD FROM FLAMMABLE MATERIALS LOCATION OF THE STOVE SMOKE PIPES 5 2 4 LOCATION THE FIREPLACE STOVE TYPE SERIES RD ON THE FLOOR 5 2 5 REQUIREMENTS FOR PASSING COMBUSTION AIS 5 2 6 INSTALLATION THE...

Page 3: ...screw cover back with screw 1 and 2 Pic 2 For security reasons the door is locked from both left and right site Before installation of the stove please check lifting door lifting up down and opening s...

Page 4: ...paint will harden and that give off smoke and a smell which starts after the fire has burned for about 10 minutes and lasts for about 15 minutes See to it that there is ample ventilation in the room...

Page 5: ...series RD may not be from combustible materials respectively should be used for good thermal insulation Combustion pipe must be fitted to the fireplace chimney s mouthpiece furnace type series RD so t...

Page 6: ...CM AIR INLET OPEN ALSO FOR EXTERNAL AIR INLET IS LOCATED AT THE BACK SIDE DOWN OF THE FIREPLACE STOVE SEE PIC 6 Setting up the high of fireplace insert can be in two ways 1 to do a special higher flo...

Page 7: ...t register We recommend that you use the design grill M design which have many advantages Pic 7 8 NOTE The circulation of hot air is required to be in the room because of the reason to do not produce...

Page 8: ...meter 200 mm Some chimneys may require different standard diameters In this case refer to the table for the height of the chimney and by reducing the possibility of reduction Chimney fireplace insert...

Page 9: ...gal requirement but it also makes sense for your own safety Refractory bricks babble may still work perfectly even if they are cracked However if there are missing pieces of bricks material bricks mus...

Page 10: ...tove type series RD During operating the fireplace stove type series RD is forbidden give the hand into the flow of heated air because of the security reasons there is too high temperature Fire in the...

Page 11: ...serial number see Pic 15 TYPE fireplace stove RD RD 750 RD 1000 Rated thermal power kW 14 7 15 7 Average efficiency 82 82 Heat flow into the space kW 14 7 15 7 Power range kW 4 2 15 5 2 16 Flue gas te...

Page 12: ...885 705 1327 5 1362 5 453 4 2 6 0 933 508 562 1091 750 RD...

Page 13: ...1135 705 1327 5 562 1220 63 1183 4 2 6 0 210 508 1362 5 1341 453 1000 RD...

Page 14: ...uctions Assembly installation or repair by a third party including the buyer Heat cracks which normally occur in the mantel In cases where changes have been made to the appliance without our consent I...