must be positioned so as to maintain the safety distance from any flammable materials that could not fire.
However, if you decide to carry out the work on your own, we advise you to do the following:
Refer to the terms and conditions of our contract of guarantee
Ask your supplier for advice.
2.2
LIST OF STANDARDS TO BE OBSERVED DURING ASSEMBLY AND
OPERATIONS
The fireplace type „RD“ complies with STN EN 13229. For installation and operation of the fireplace
type „RD“ should proceed in accordance with STN 92 0300 „Local fire safety appliances and heat sources“ and
STN 73 4201 „The design of chimneys and flues“.
2.3
SAFE DISTANCE FIREPLACE STOVES TYPE „RD“ FROM FLAMMABLE
MATERIALS, LOCATION OF THE STOVE AND SMOKE PIPES
Fireplace type series „RD“ must be installed in accordance with Decree MV SR No. 95/2004 statute,
coll establishing specifications and requirements for fire safety during installations and operation of heating
appliances, electro thermal appliances and central heating installations and the constructions and use of chimneys
and flues. It is also necessary to respect the STN 73 4210 „Running of the chimneys and flues and connecting
fuel appliances“. The manufacturer recommends the installation of the fireplace furnace type series
„RD“conducted by qualified Professional who is responsible for the material used for installation. The
manufacturer is responsible for the delivered product.
When installing the fireplace type series „RD“ must be complied with 1000 mm safety clearance from
combustible materials
The fireplace type series „RD“ must be installed so that before it left space on the layout, about 1x1 m.
Basis respectively base under fireplace type series „RD“ must be straight fire material and must
withstand heat stress. Also, wall and ceiling material, which the fireplace type series „RD“ may not be from
combustible materials, respectively should be used for good thermal insulation.
Combustion pipe must be fitted to the fireplace chimney`s mouthpiece furnace type series „RD“ so that
it is firmly and tightly connected.
The combustion pipe might be of black respectively stainless steel pipes and elbows. The flue
connection must be made by the shortest route to the flue by STN 73 4210. The combustion pipe should be
implemented and consolidate in order to be released accidentally or spontaneously. Pipes that are plugged into
each other should be inserted in the direction of flow of exhaust gases. Where the flue passes through building
structure, which contains flammable materials or surface modified flammable materials should be insulated to
protect the crossing design and implement in accordance with Decree MV SR No. 95/2004 statute.
Connection the combustion pipe of the furnace type series „RD“ can only be the chimney, which has
been expertly tested. Based on expert examination of the appliance flue connection and issue a professionally
qualified person „Certificate examination on implementation of the chimney, where a professionally qualified
person to deliver state of the chimney and flue for their safe and reliable operation.
2.4
LOCATION THE FIREPLACE STOVE TYPE SERIES „RD“ ON THE FLOOR
In the place of installation fireplace insert type series „RD“ on the floor must be ensured a minimum
floor load 1000 kg.m
-2
. The floor before the fireplace insert type series „RD“ must be fire-resistant material at
a distance of at least 1000 mm from front wall of the fireplace insert type series „RD” .
2.5
REQUIREMENTS FOR PASSING COMBUSTION AIS
The fireplace furnace type series „RD“ can be placed directly in the heated respectively outside the
heated space. The combustion of fuel used airs from the area where the fireplace furnace is, or it is possible to
transport external admission of air and connect it according to the point 2.7. In case of insufficient ventilation of