![LZR FLATSCAN REV PZ User Manual Download Page 4](http://html1.mh-extra.com/html/lzr/flatscan-rev-pz/flatscan-rev-pz_user-manual_1954331004.webp)
4
x
ON
OFF
-
NO/NO
-
1
2
a
b
a
b
CLASS 1 LASER PR
ODUCT
CAUTION! CLASS 3R L
ASER
RADIATION ACCESSIBLE
DURING INSTALLATION.
AVOID DIRECT EYE EXPOSURE!
>20 cm
INSTALLATION
DIP SWITCH
DIP 2 ENVIRONMENT
DIP 3 BACKGROUND
DIP 4 MONITORING
standard
critical*
DIP 5 (NOT USED)
DIP 1 OUTPUT CONFIGURATION
active high
active low
INSTALLATION OF THE SENSOR
Install the sensor at the right position and fix it with the screws.
* When DIP2 is OFF (critical environments),
testbody
CB
(DIN 18650-1) and
testbody CB
(EN 16005) &
testbody
CC (DIN 18650-1) might not be detected.
We recommend starting with DIP switch settings since they might be inaccessible when the product is mounted.
Switch to CRITICAL when external disturbances are likely to
cause unwanted detections.
Switch to OFF when there is no background
(e.g. glass floor).
Make sure the
front side of the
sensor (where
you'll find the yel-
low sticker) faces
towards the out-
side of the door
Make sure the
front side of the
sensor (where
you'll find the
yellow sticker)
faces towards the
rotation axis of the
door.
After changing a DIP-switch, the orange LED flashes.
A LONG push on the push button confirms the settings.
on
NC/NC
front side
front side
> 3 sec.
off
RECESSED VERSION
SURFACE VERSION
Place the template in the right position.
Drill 2 screw holes and 1* cable route hole to
pass the cable.
* according to the structure of the door on site.
Remove the cover with a screwdriver.
Firmly screw the sensor to the door frame. If you are
installing the sensor on a curved surface, make sure
the screws are not too tight.
Pass the cable through the cable route hole (a or b).
1) Recessed on the fixed ceiling
2) Recessed on the moving ceiling
Make sure that the
distance between the
centre of the sensor
and the leading post
is not smaller than
20 cm.
Same as above.
Also, make sure the
detection curtain is
positioned directly in
front of the main clo-
sing edge
cable route hole
screw hole