LZR FLATSCAN REV PZ User Manual Download Page 4

4

x

ON

OFF

-

NO/NO

-

1

2

a

b

a

b

   CLASS 1 LASER PR

ODUCT

  CAUTION! CLASS 3R L

ASER

    RADIATION ACCESSIBLE

    DURING INSTALLATION.
    AVOID DIRECT EYE EXPOSURE!

>20 cm

INSTALLATION

DIP SWITCH

DIP  2      ENVIRONMENT         

DIP  3      BACKGROUND               

DIP 4   MONITORING              

standard

critical*

DIP  5    (NOT  USED)          

DIP 1   OUTPUT CONFIGURATION         

active high

active low

INSTALLATION OF THE SENSOR

Install the sensor at the right position and fix it with the screws.

 * When DIP2 is OFF (critical environments), 

testbody

 

CB

 (DIN 18650-1) and 

testbody CB

 (EN 16005) &

 

testbody

 CC (DIN 18650-1) might not be detected.

We recommend starting with DIP switch settings since they might be inaccessible when the product is mounted.

Switch to CRITICAL when external disturbances are likely to 
cause unwanted detections.

Switch to OFF when there is no background 
(e.g. glass floor).

Make sure the 
front side of the 
sensor (where 
you'll find the yel-
low sticker) faces 
towards the out-
side of the door

Make sure the 

front side of the 

sensor (where 

you'll find the 

yellow sticker) 

faces towards the 

rotation axis of the 
door.

After changing a DIP-switch, the orange LED flashes.  

A LONG push on the push button confirms the settings.

on

NC/NC

front side

front side

> 3 sec.

off

RECESSED VERSION

SURFACE VERSION

Place the template in the right position.

Drill 2 screw holes and 1* cable route hole to 

pass the cable. 

* according to the structure of the door on site.

Remove the cover with a screwdriver.

Firmly screw the sensor to the door frame. If you are 

installing the sensor on a curved surface, make sure 

the screws are not too tight.

Pass the cable through the cable route hole (a or b). 

1) Recessed on the fixed ceiling

2) Recessed on the moving ceiling

Make sure that the 
distance between the 
centre of the sensor 
and the leading post 
is not smaller than 
20 cm.

Same as above. 
Also, make sure the 
detection curtain is 

 

positioned directly in 
front of the main clo-
sing edge

cable route hole 

screw hole

recommended position

Summary of Contents for FLATSCAN REV PZ

Page 1: ...U B T Z E R T I F I Z I E R U N G N A C H EN 16005 E N A B L E S A C C O R D A N C E W I T H PLEASE KEEP FOR FURTHER USE DESIGNED FOR COLOUR PRINTING User s Guide for software version SW 0200 and high...

Page 2: ...djustment screw 3 Laser screen 4 Connector 5 Push button 6 Laser window protection 7 Front cover 8 DIP switch 9 Power cable DESCRIPTION The LZR FLATSCAN REV PZ is a safety sensor for automatic revolvi...

Page 3: ...fety The manufacturer of the sensor cannot be held responsible for incorrect installations or inappropriate adjustments of the sensor The warranty is void if unauthorized repairs are made or attempted...

Page 4: ...low sticker faces towards the out side of the door Make sure the front side of the sensor where you ll find the yellow sticker faces towards the rotation axis of the door After changing a DIP switch...

Page 5: ...visible spots Try to position the red spots as close to the door as possible Just make sure the door is not detected If 2 m mounting height d 4cm If 3 m mounting height d 5cm If 4 m mounting height d...

Page 6: ...red while calculating 3 Wait until the sensor flashes green again Stretch out your arm in front of you and make an up and down movement to define the right left limit of the detection field The LED f...

Page 7: ...case of false detection button and are not recommended When DIP2 is OFF changes automatically to 10 cm Note that the uncovered zone reduces the detection field not only at the bottom but also on the...

Page 8: ...s code To end an adjustment session always lock the sensor ADJUSTING ONE OR MORE PARAMETERS DETECTION FIELD ADJUSTMENT Launch detection field Teach in refer to the teach in process on page 6 Launch en...

Page 9: ...output redirection and configuration enable disable the LED when there is a detection disable the output and LED for during 15 minutes and can be useful during an installation a mechanical teach in o...

Page 10: ...sensor Replace sensor The sensor does not react when powered Test error Check voltage between red and blue wires The service mode is activated Exit the service mode It is not possible to adjust a sett...

Page 11: ...d 1 Make sure the laser window is not scratched If it is replace sensor 2 Remove all masking elements insects spider web flexible tube laser window protection 3 Verify if the laser window is dirty and...

Page 12: ...r Testbody CB EN CC DIN 300 mm x 100 mm x 65 mm foot shaped Optical characteristics IEC EN 60825 1 Wavelength 905 nm output power 0 1 mW CLASS 1 Wavelength 635 nm output power 1 mW CLASS 2 visible spo...