TECHNICAL SPECIFICATIONS

TH

IS U

SE

R'

S G

U

ID

E I

S A

N I

N

FO

R

M

A

TI

V

E D

O

C

U

M

EN

T A

N

D C

A

N N

O

T B

E S

EE

N A

S A C

O

M

M

IT

M

EN

T O

F R

ES

U

LT

.

BEA hereby declares that the equipment type Flatscan REV-PZ is in compliance with European Directives 2006/42/EC (Machinery), 
2011/65/EU (RoHS) and 2014/30/EU (EMC). The full text of the EU declaration of conformity is available on our website
Notified Body for EC-type inspection: 0044 - TÜV NORD CERT GmbH, Langemarckstr. 20, D-45141 Essen
EC-type examination certificate number: 44 205 16129701
P. Gardier, Angleur, 2018

This product should be disposed of separately from unsorted municipal waste

©

BE

A

 

 | 

O

ri

gi

na

l i

ns

tr

uc

ti

on

s

 

47

.0

333

 / V

4 - 0

5.

21

Technology

LASER scanner, time-of-flight measurement

Detection mode

Presence

Installation height

Min. : 2 m
Max. :                       
                               Pinch zone (fixed installation)            Sword zone (moving installation)
EN 16005                         4 m                                                4 m
DIN 18650-1                    3.5 m                                             4 m
with reflectivity of 8 %    5 m                                                5 m

Opening angle

90°

Angular resolution

0.23° (400 spots within 90°)

Testbody

Testbody CA (EN & DIN) : 700 mm x 300 mm x 200 mm
Testbody CB (DIN) : 50 mm cylinder
Testbody CB (EN) & CC (DIN) : 300 mm x 100 mm x 65 mm (foot-shaped)

Optical characteristics 

IEC/EN 60825-1

Wavelength 905 nm; output power < 0.1 mW ; CLASS 1 
Wavelength 635 nm; output power < 1 mW ; CLASS 2 - visible spot

Supply voltage

12-24V DC ± 15% (

The Equipment must be powered by a SELV limited power source ensuring double 

insulation between primary voltages and the Equipment supply. The supply current should be limited to 
1.5 A)

Power consumption

≤ 2.2 W

Response time

Max. 90 ms

Output

1 optocoupler ( galvanic isolation - polarity free )
Max. switching voltage: 42V AC/ 60V DC
Max. switching current: 100 mA
1 Relay ( free of potential change-over contact )
Max. contact voltage: 42V AC / 60V DC
Max. contact current: 1.0A ( resistive )
Max. switching power: 30W ( DC ) / 60VA ( AC )

LED-signals

1 bi-coloured LED: detection/output status

Dimensions

Recessed version
Surface version

178 mm (L) × 85 mm (H) × 53 mm (D)

168 mm (L) × 93 mm (H) × 42.5 mm (D)

Material - Colour

PC/ABS - Black / Aluminum

Tilt angles

0° to +5° 

Protection degree

IP54 (IEC/EN 60529)

Temperature range

-30°C to +60°C if powered

Humidity

0-95 % non-condensing

Vibrations

< 2 G

Compliance

EN 12978, EN ISO 13849-1 PL “d” / CAT2, IEC/EN 61508 SIL2
                        Pinch zone (fixed installation)                    Sword zone (moving installation)
EN 16005         Testbody CA                                             Testbody CB
DIN 18650-1    Testbody CA & CB                                     Testbody CC

Specifications are subject to change without prior notice. All values are measured in specific conditions.

Summary of Contents for FLATSCAN REV PZ

Page 1: ...U B T Z E R T I F I Z I E R U N G N A C H EN 16005 E N A B L E S A C C O R D A N C E W I T H PLEASE KEEP FOR FURTHER USE DESIGNED FOR COLOUR PRINTING User s Guide for software version SW 0200 and high...

Page 2: ...djustment screw 3 Laser screen 4 Connector 5 Push button 6 Laser window protection 7 Front cover 8 DIP switch 9 Power cable DESCRIPTION The LZR FLATSCAN REV PZ is a safety sensor for automatic revolvi...

Page 3: ...fety The manufacturer of the sensor cannot be held responsible for incorrect installations or inappropriate adjustments of the sensor The warranty is void if unauthorized repairs are made or attempted...

Page 4: ...low sticker faces towards the out side of the door Make sure the front side of the sensor where you ll find the yellow sticker faces towards the rotation axis of the door After changing a DIP switch...

Page 5: ...visible spots Try to position the red spots as close to the door as possible Just make sure the door is not detected If 2 m mounting height d 4cm If 3 m mounting height d 5cm If 4 m mounting height d...

Page 6: ...red while calculating 3 Wait until the sensor flashes green again Stretch out your arm in front of you and make an up and down movement to define the right left limit of the detection field The LED f...

Page 7: ...case of false detection button and are not recommended When DIP2 is OFF changes automatically to 10 cm Note that the uncovered zone reduces the detection field not only at the bottom but also on the...

Page 8: ...s code To end an adjustment session always lock the sensor ADJUSTING ONE OR MORE PARAMETERS DETECTION FIELD ADJUSTMENT Launch detection field Teach in refer to the teach in process on page 6 Launch en...

Page 9: ...output redirection and configuration enable disable the LED when there is a detection disable the output and LED for during 15 minutes and can be useful during an installation a mechanical teach in o...

Page 10: ...sensor Replace sensor The sensor does not react when powered Test error Check voltage between red and blue wires The service mode is activated Exit the service mode It is not possible to adjust a sett...

Page 11: ...d 1 Make sure the laser window is not scratched If it is replace sensor 2 Remove all masking elements insects spider web flexible tube laser window protection 3 Verify if the laser window is dirty and...

Page 12: ...r Testbody CB EN CC DIN 300 mm x 100 mm x 65 mm foot shaped Optical characteristics IEC EN 60825 1 Wavelength 905 nm output power 0 1 mW CLASS 1 Wavelength 635 nm output power 1 mW CLASS 2 visible spo...