TROUBLESHOOTING

The ORANGE LED is on 
permanently.

The sensor encounters a 
memory problem.

Send the sensor back for a technical check-up.

The ORANGE LED flashes 
quickly.

DIP-switch setting awaiting 
confirmation.

Corfirm the DIP-switch setting: long push on the push 
button.

The ORANGE LED flashes
1 x every 3 seconds.

The sensor signals an 
internal fault.

Cut and restore power supply.
If orange LED flashes again, replace sensor.

The ORANGE LED flashes
2 x every 3 seconds.

Power supply is out of limit.

1

Check power supply (tension, capacity).

2

Reduce the cable length or change cable.

The ORANGE LED flashes 
3 x every 3 seconds.

The sensor signals an 
internal fault.

Cut and restore power supply.
If orange LED flashes again, replace sensor.

The ORANGE LED flashes 
4 x every 3 seconds.

Something close to the sensor 

is masking 

part of the detection field.

1

Make sure the laser window is not scratched. 
If it is, replace sensor.

2

Remove all masking elements (insects, spider web, 
flexible tube, laser window protection).

3

Verify if the laser window is dirty and clean it with 
compressed air. Then wipe it carefully with a damp 
and clean microfibre cloth if necessary
(attention: the surface of the laser window is delicate)

The sensor does not see its 

background.

Switch DIP 3 to off (deactivates background).

The ORANGE LED flashes 
5 x every 3 seconds.

Teach-in error

1

Check whether all teach-in requirements are fulfilled 
and launch a new teach-in.

2

Adjust the tilt angle of the laser curtain and launch a 
new teach-in.

3

Make sure there are no objects on the ground during 
teach-in and launch a new teach-in.

The ORANGE LED flashes 
6 x every 3 seconds.

Installation height higher

than limitation.

Press the push button during at least 5 seconds to 
confirm the installation height of sensor is higher 
than 4m. Note that the sensor does not comply with 
DIN 18650-1 and EN 16005 above this height. 

6

5

2

1

3

4

Summary of Contents for FLATSCAN REV PZ

Page 1: ...U B T Z E R T I F I Z I E R U N G N A C H EN 16005 E N A B L E S A C C O R D A N C E W I T H PLEASE KEEP FOR FURTHER USE DESIGNED FOR COLOUR PRINTING User s Guide for software version SW 0200 and high...

Page 2: ...djustment screw 3 Laser screen 4 Connector 5 Push button 6 Laser window protection 7 Front cover 8 DIP switch 9 Power cable DESCRIPTION The LZR FLATSCAN REV PZ is a safety sensor for automatic revolvi...

Page 3: ...fety The manufacturer of the sensor cannot be held responsible for incorrect installations or inappropriate adjustments of the sensor The warranty is void if unauthorized repairs are made or attempted...

Page 4: ...low sticker faces towards the out side of the door Make sure the front side of the sensor where you ll find the yellow sticker faces towards the rotation axis of the door After changing a DIP switch...

Page 5: ...visible spots Try to position the red spots as close to the door as possible Just make sure the door is not detected If 2 m mounting height d 4cm If 3 m mounting height d 5cm If 4 m mounting height d...

Page 6: ...red while calculating 3 Wait until the sensor flashes green again Stretch out your arm in front of you and make an up and down movement to define the right left limit of the detection field The LED f...

Page 7: ...case of false detection button and are not recommended When DIP2 is OFF changes automatically to 10 cm Note that the uncovered zone reduces the detection field not only at the bottom but also on the...

Page 8: ...s code To end an adjustment session always lock the sensor ADJUSTING ONE OR MORE PARAMETERS DETECTION FIELD ADJUSTMENT Launch detection field Teach in refer to the teach in process on page 6 Launch en...

Page 9: ...output redirection and configuration enable disable the LED when there is a detection disable the output and LED for during 15 minutes and can be useful during an installation a mechanical teach in o...

Page 10: ...sensor Replace sensor The sensor does not react when powered Test error Check voltage between red and blue wires The service mode is activated Exit the service mode It is not possible to adjust a sett...

Page 11: ...d 1 Make sure the laser window is not scratched If it is replace sensor 2 Remove all masking elements insects spider web flexible tube laser window protection 3 Verify if the laser window is dirty and...

Page 12: ...r Testbody CB EN CC DIN 300 mm x 100 mm x 65 mm foot shaped Optical characteristics IEC EN 60825 1 Wavelength 905 nm output power 0 1 mW CLASS 1 Wavelength 635 nm output power 1 mW CLASS 2 visible spo...

Reviews: