8
Miscellaneous patterns
• Multi-burst
• Frequency Sweep
• Pathological EQ/PLL (split)
• Moving Boxes (Dynamic pattern)
• EBU AV Sync (Dynamic pattern)**
(
Note:
leaving the EBU menu will cause the sequence to stop)
Nav:
HOME > PATTERN > SDI (X)> MISCELLANEOUS
(select pattern)
**For a compressive guide on the use of the EBU AV sync test pattern, please visit
our website for more information:
www.lynx-technik.com/en/products/testor/ebu-av-sync-pattern
Using 3D (stereoscopic) Test Patterns
3D (stereoscopic) test patterns, consisting of two 1.5G HD-SDI streams
for Left Eye (LE) and Right Eye (RE) can be selected. This is accomplished
by assigning the individual 3D patterns for LE and RE from the provided
3D patterns. The SDI format has to be set to one of the 1.5G HD-SDI
standards (not 3G-SDI).
By default, these two different signals will be streamed as two individual
1.5G SDI streams for LE and RE, one per BNC connector, according to
SMPTE 292-1.
As an alternative way of streaming these two 1.5G HD-SDI signals, the
user can enable the “3G Level B Dual Stream” mode. When enabled, the
two individual 1.5G signals will be multiplexed into a single 3G-SDI Level B
Dual Stream signal according to SMPTE 425. In this case, both SDI outputs
have the same signal.
Two dedicated 3D patterns are provided which provide a 3D effect when
viewed in a 3D environment. These comprise of two slightly different
patterns for left eye (LE) and right eye (RE).