Lynx PTG 1802 User Manual Download Page 7

6

3G-SDI (3Gbit) Operation

The 3G-SDI formats (1080p/50/59/60) can be streamed in one of three

 

possible formats:

• Two individual 1.5G SDI streams, one per BNC connector. SMPTE 372

   (Dual Link)
• Two individual 1.5G SDI streams multiplexed into one 3G-SDI stream.

   SMPTE 425 Level B (Dual Link)
• One real 3G-SDI stream. SMPTE 425 Level A (Direct

 Mapping)

The factory default setting is specified as “3G-SDI, SMPTE 425 Level A”
To set the 3G streaming modes:

  Navigation:

 

HOME > STANDARD > 3G STREAMING FORMAT

 

(set mode)

Setting Video Format

The Testor lite 3G can be configured to provide test signals in the 

following formats/standards:

SMPTE 259M (SDTV):

525 (480i/59) / 625 (576i/50)

SMPTE 292M (1.5G HDTV)

[1080i 60], [1080i 59.94], [1080i 50], [1080p 30], [1080p 29.97],

[1080p 25], [1080p 24], [1080psf 25], [1080psf 24], [1080psf 23.97],

[720p 60], [720p 59.94], [720p 50], [720p 30], [720p 29.97], [720p 25], 

[720p 24], [720p 23.97]

SMPTE 424M (3G HDTV)

[1080p 60], [1080p 59.94], [1080p 50]
2 x SDI outputs are provided. The signal format and frequency is identical 

on both outputs but independent patterns can be selected for each 

output. (exeptions are dynamic patterns, which are on both outputs)

  Navigation:

 

HOME > STANDARD

 (select video format)

Summary of Contents for PTG 1802

Page 1: ...Testor lite 3G PTG 1802 User Guide Revision 1 3 Firmware 715 and above LYNXTechnik AG Broadcast Television Equipment...

Page 2: ...3D patterns 3D patterns Selecting Overlays Circle Overlay Text Overlay Cage Markers Overlay Setting Audio Audio Generators Audio Embedders Sync Output User Settings System Settings Battery Timeout Os...

Page 3: ...SB Port Power Charging Firmware updates Navigation Menu Battery Level Audio Settings Selected Pattern Audio Group Connections Layout The image below shows the connections controls and basic layout of...

Page 4: ...ed to operate the unit The basic touch screen button functions are shown below This type of button triggers a function i e if pressed the selected function will be set as a direct result This type of...

Page 5: ...al temperature sensor and will stop charging if the battery temperature is too high This can also happen if the unit is charged and operated at the same time Charge Times When the battery is empty the...

Page 6: ...the POWER button for 5 seconds or longer will also switch off the unit Automatic Shutdown With no user activity touch screen use the unit will automatically shut down after a given time period to pre...

Page 7: ...FORMAT set mode Setting Video Format The Testor lite 3G can be configured to provide test signals in the following formats standards SMPTE 259M SDTV 525 480i 59 625 576i 50 SMPTE 292M 1 5G HDTV 1080i...

Page 8: ...or Bar 100 100 Full Field Color Bar 100 75 Split Color Bars 100 100 Split Color Bars 100 75 SMPTE 219 Bars Navigation HOME PATTERN SDI X COLORBARS select pattern Static Flat Field Patterns Full Field...

Page 9: ...y assigning the individual 3D patterns for LE and RE from the provided 3D patterns The SDI format has to be set to one of the 1 5G HD SDI standards not 3G SDI By default these two different signals wi...

Page 10: ...verlays are the same for both outputs but can be turned ON and OFF independently Circle Overlay A 16 9 or 4 3 circle overlay can be superimposed The circle center point of the circle is the geometric...

Page 11: ...enerators Two audio generators are provided each generator has four channels and each channel can be configured independently The following selections are available Frequencies 50Hz 100Hz 200Hz 250Hz...

Page 12: ...Sync BNC connector of the Testor lite 3G can be configured as a reference input or as a sync output When the module is set to Free Run mode the Sync BNC will output a sync signal When set to Genlock...

Page 13: ...Frequency deviation is adjustable 50ppm around the calibrated default value in increments of 1 ppm The factory calibrated default value is easily restored Nav HOME SETTINGS OSCILLATOR FREQUENCY make c...

Page 14: ...operating temperature is 5 to 40 C The battery has an internal temperature sensor and will stop charging if the battery temperature is too high This can also happen if the unit is charged and operated...

Page 15: ...which the LYNX Technik AG service center is located Customer shall be responsible for payment of all shipping charges duties taxes and any other charges for products returned to any other locations T...

Page 16: ...he battery temperature is too high This can also happen if the unit is charged and operated at the same time Physical Size including connectors 130 x 77 x 23mm 5 12 x 3 03 x 0 91 inches Weight 250g 8...