background image

Reference Manual C DA 5005 Version1.0

 

 

Page 3  

 

Warranty 

 

LYNX Technik AG warrants that the product will be free from 
defects in materials and workmanship for a period of two (2) 

year from the date of shipment. If this product proves defective 
during the warranty period, LYNX Technik AG at its option will 
either repair the defective product without charge for parts and 
labor, or will provide a replacement in exchange for the 

defective product. 
 
In order to obtain service under this warranty, customer must 
notify LYNX Technik of the defect before expiration of the 

warranty period and make suitable arrangements for the 
performance of service. Customer shall be responsible for 
packaging and shipping the defective product to the service 

center designated by LYNX Technik, with shipping charges 
prepaid. LYNX Technik shall pay for the return of the product to 
the customer if the shipment is within the country which the LYNX 
Technik service center is located. Customer shall be responsible 
for payment of all shipping charges, duties, taxes and any other 
charges for products returned to any other locations. 

 
This warranty shall not apply to any defect, failure, or damage 
caused by improper use or improper or inadequate 
maintenance and care. LYNX Technik shall not be obligated to 

furnish service under this warranty a) to repair damage resulting 
from attempts by personnel other than LYNX Technik 
representatives to install, repair or service the product; b) to 
repair damage resulting from improper use or connection to 

incompatible equipment; c) to repair any damage or 
malfunction caused by the use of non LYNX Technik supplies; or 
d) to service a product which has been modified or integrated 
with other products when the effect of such modification or 
integration increases the time or difficulty servicing the product. 

 

THIS WARRANTY IS GIVEN BY LYNX TECHNIK WITH RESPECT TO THIS 

PRODUCT IN LIEU OF ANY OTHER WARRANTIES, EXPRESS OR 
IMPLIED. LYNX TECHNIK AND ITS VENDORS DISCLAIM ANY IMPLIED 
WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR 
PURPOSE. LYNX TECHNIK`S RESPONISIBILITY TO REPAIR AND 

REPLACE DEFECTIVE PRODUCTS IS THE SOLE AND EXCLUSIVE 
REMEDY PROVIDED TO THE CUSTOMER FOR BREACH OF THIS 
WARRANTY. LYNX TECHNIK AND ITS VENDORS WILL NOT BE LIABLE 
FOR ANY INDIRECT, SPECIAL, INCIDENTAL, OR CONSEQUENTAL 

DAMAGES IRRESPECTIVE OF WHETHER LYNX TECHNIK OR THE 
VENDOR HAS ADVANCE NOTICE OF THE POSSIBILITY OF SUCH 
DAMAGES. 

Summary of Contents for C DA 5005

Page 1: ...Series 5000 LYNX Technik AG Brunnenweg 3 D 64331 Weiterstadt Germany www lynx technik com Reference Manual C DA 5005 5 Channel SDI to CVBS Converter CardModule Version 1 0...

Page 2: ...written permission of LYNX Technik AG LYNX Technik AG may have patents patent applications trademarks copyrights or other intellectual property rights covering the subject matter in this document Exce...

Page 3: ...ranty shall not apply to any defect failure or damage caused by improper use or improper or inadequate maintenance and care LYNX Technik shall not be obligated to furnish service under this warranty a...

Page 4: ...s operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful in...

Page 5: ...unctional Diagram 8 Module Layout 8 Connections 10 Video Connections 10 Installation 11 Settings and Control 12 Control Modes 13 Switch Settings 14 Switch Function Detail 15 Factory Preset Condition 1...

Page 6: ...Reference Manual C DA 5005 Version1 0 Page 6 This page is intentionally left blank...

Page 7: ...a variety of features which includes PAL or NTSC operation auto detect Internal color bars Internal 2x over sampling 27MHz Local DIP switches and LED s for control and status monitoring Microprocessor...

Page 8: ...m Figure 1 below is the basic functional diagram for the C DA 5005 CardModule Figure 1 C DA 5005 Functional Diagram Module Layout Figure 2 shows the physical layout of the C DA 5005 CardModule and als...

Page 9: ...Reference Manual C DA 5005 Version1 0 Page 9 Figure 2 Module Layout...

Page 10: ...rd 75 Ohm BNC connectors Connection is self explanatory We recommend the use of high quality video cables for digital video connections to reduce the risk of interference or errors due to excessive ca...

Page 11: ...located b Remove the blank connection panel from the rear of the rack if fitted c Install the rear connection panel using the screws supplied Do not tighten the screws fully d Slide the card module i...

Page 12: ...and controlled locally using integral 8 position dip switch and the multifunction switch or from remote when using one of the optional controllers and control software Once set all settings are automa...

Page 13: ...Test Signal ON and RED for Signal Lost Alarm Enable Mode This mode is used to define which channels are part of the combined alarm indication provided on the single Alarm LED Any channels used or unus...

Page 14: ...form part of the combined alarm reporting for the module Any channel used or unused can be added or removed from the Alarm configuration CHANNEL STATUS MODE Switch Setting Function 1 Toggle on off on...

Page 15: ...he module This is because all settings can be changed from the remote control system This overrides the local dip switches regardless of Switch 1 ON OFF setting To ensure the module reads the local di...

Page 16: ...Switch 3 This is used to select what type signal is output for channels with input signal lost ON selects Color Bars and OFF selects black as output Dip Switch 4 8 CHANNEL STATUS MODE Switch 4 Channel...

Page 17: ...tus Mode Test Signal Color Bars Test Signal OFF Normal operation for all channels All channels Alarm Enabled If this is the mode of operation required then no adjustments are necessary Auto Store If n...

Page 18: ...lower edge of the module which can be seen when the rack front cover is fitted The status of this LED is defined by the alarm enable settings as explained above LED OFF indicates power is lost or ther...

Page 19: ...selected on the control system there is a locate button on the top of the GUI Locate Function in Control System When Locate is selected the status indicator on the GUI and the module LED s will flash...

Page 20: ...NC Impedance 75 Ohms Operating Modes Conversion D A conversion for SDI Signals TV Standard NTSC or PAL Auto detect Test Internal Color Bars Performance Quantization 8 Bits Sampling 27 MHz 2x Over samp...

Page 21: ...Card Frame R CT 5010 Rack Bus Extension for the R FR 5010 Card Frame In combination with R CT 5020 Parts List Due to the very dense design and miniature surface mount technology the module is not fie...

Page 22: ...stributor for assistance We offer a fixed cost service exchange program for defective Series 5000 CardModules out of Warranty Please contact your distributor or check our web site for details on this...

Page 23: ...Technik can be contacted directly using the information below Address LYNX Technik AG Brunnenweg 3 D 64331 Weiterstadt Germany Website www lynx technik com E Mail info lynx technik com LYNX Technik ma...

Page 24: ...Reference Manual C DA 5005 Version1 0 Page 24 This page is intentionally left blank...

Page 25: ...Reference Manual C DA 5005 Version1 0 Page 25 Notes...

Reviews: