background image

Reference Manual C DA 5005 Version1.0

 

 

Page 19  

 

Locate Function 

For larger systems which may have multiple 

MiniModules of the same type in a single rack, or 
multiple rack systems on a large central control 

system we have added a useful utility which will 

help to visually locate a suspect module quickly 
(When used in conjunction with the optional control 

system and software) 

 

Once the specific module has been selected on 

the control system there is a locate button on the 

top of the GUI: 
 

 

 
 

 

 
 

 

                       Locate Function in Control System 

 

When Locate is selected the status indicator on the 

GUI and the module LED`s will flash yellow in the 

following continuous sequence.  

 

3 short flashes…. Pause…. 3 short flashes … 

 

This uses the alarm LED located on the front of the 
module and in some cases any channel or status 

LED`s that may be used in the module. 

 
Use of the locate function will not interfere with the 

normal operation of the module. 

 
For more details on this feature please check the 

documentation supplied with the controller 

software. 

 

Summary of Contents for C DA 5005

Page 1: ...Series 5000 LYNX Technik AG Brunnenweg 3 D 64331 Weiterstadt Germany www lynx technik com Reference Manual C DA 5005 5 Channel SDI to CVBS Converter CardModule Version 1 0...

Page 2: ...written permission of LYNX Technik AG LYNX Technik AG may have patents patent applications trademarks copyrights or other intellectual property rights covering the subject matter in this document Exce...

Page 3: ...ranty shall not apply to any defect failure or damage caused by improper use or improper or inadequate maintenance and care LYNX Technik shall not be obligated to furnish service under this warranty a...

Page 4: ...s operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful in...

Page 5: ...unctional Diagram 8 Module Layout 8 Connections 10 Video Connections 10 Installation 11 Settings and Control 12 Control Modes 13 Switch Settings 14 Switch Function Detail 15 Factory Preset Condition 1...

Page 6: ...Reference Manual C DA 5005 Version1 0 Page 6 This page is intentionally left blank...

Page 7: ...a variety of features which includes PAL or NTSC operation auto detect Internal color bars Internal 2x over sampling 27MHz Local DIP switches and LED s for control and status monitoring Microprocessor...

Page 8: ...m Figure 1 below is the basic functional diagram for the C DA 5005 CardModule Figure 1 C DA 5005 Functional Diagram Module Layout Figure 2 shows the physical layout of the C DA 5005 CardModule and als...

Page 9: ...Reference Manual C DA 5005 Version1 0 Page 9 Figure 2 Module Layout...

Page 10: ...rd 75 Ohm BNC connectors Connection is self explanatory We recommend the use of high quality video cables for digital video connections to reduce the risk of interference or errors due to excessive ca...

Page 11: ...located b Remove the blank connection panel from the rear of the rack if fitted c Install the rear connection panel using the screws supplied Do not tighten the screws fully d Slide the card module i...

Page 12: ...and controlled locally using integral 8 position dip switch and the multifunction switch or from remote when using one of the optional controllers and control software Once set all settings are automa...

Page 13: ...Test Signal ON and RED for Signal Lost Alarm Enable Mode This mode is used to define which channels are part of the combined alarm indication provided on the single Alarm LED Any channels used or unus...

Page 14: ...form part of the combined alarm reporting for the module Any channel used or unused can be added or removed from the Alarm configuration CHANNEL STATUS MODE Switch Setting Function 1 Toggle on off on...

Page 15: ...he module This is because all settings can be changed from the remote control system This overrides the local dip switches regardless of Switch 1 ON OFF setting To ensure the module reads the local di...

Page 16: ...Switch 3 This is used to select what type signal is output for channels with input signal lost ON selects Color Bars and OFF selects black as output Dip Switch 4 8 CHANNEL STATUS MODE Switch 4 Channel...

Page 17: ...tus Mode Test Signal Color Bars Test Signal OFF Normal operation for all channels All channels Alarm Enabled If this is the mode of operation required then no adjustments are necessary Auto Store If n...

Page 18: ...lower edge of the module which can be seen when the rack front cover is fitted The status of this LED is defined by the alarm enable settings as explained above LED OFF indicates power is lost or ther...

Page 19: ...selected on the control system there is a locate button on the top of the GUI Locate Function in Control System When Locate is selected the status indicator on the GUI and the module LED s will flash...

Page 20: ...NC Impedance 75 Ohms Operating Modes Conversion D A conversion for SDI Signals TV Standard NTSC or PAL Auto detect Test Internal Color Bars Performance Quantization 8 Bits Sampling 27 MHz 2x Over samp...

Page 21: ...Card Frame R CT 5010 Rack Bus Extension for the R FR 5010 Card Frame In combination with R CT 5020 Parts List Due to the very dense design and miniature surface mount technology the module is not fie...

Page 22: ...stributor for assistance We offer a fixed cost service exchange program for defective Series 5000 CardModules out of Warranty Please contact your distributor or check our web site for details on this...

Page 23: ...Technik can be contacted directly using the information below Address LYNX Technik AG Brunnenweg 3 D 64331 Weiterstadt Germany Website www lynx technik com E Mail info lynx technik com LYNX Technik ma...

Page 24: ...Reference Manual C DA 5005 Version1 0 Page 24 This page is intentionally left blank...

Page 25: ...Reference Manual C DA 5005 Version1 0 Page 25 Notes...