Installation 

 

Caution 

The CardModule is shipped in a 

protective anti-static bag. Please take 
suitable precautions to avoid static 

discharge onto any part of the PCB or 

components when handling module or 
serious damage could result. 

 

Each Card Module is supplied with a rear 
connection panel and two mounting screws. 

Please follow the following procedure for 

installation of the card module into the Series 5000 
Card Frame. 

 

a)

 

Select a slot in the card frame where the 
CardModule will be located 

b)

 

Remove the blank connection panel from the 

rear of the rack (if fitted) 

c)

 

Install the rear connection panel using the 

screws supplied. Do not tighten the screws fully 

d)

 

Slide the card module into the card frame and 
carefully check the CardModule easily 

connects to the rear connection plate. The 
card should fit easily and should not require 

excessive force to insert, if you feel any 

resistance, there could be something wrong 
with the rear connection panel location. Do not 

try and force the connection. Remove the rear 

connection panel and check alignment with 

the CardModule. 

e)

 

Insert and remove the CardModule a few times 

to ensure correct alignment and then tighten 
the two screws to secure the rear connection 

plate 

 

 

Summary of Contents for C DA 5005

Page 1: ...Series 5000 LYNX Technik AG Brunnenweg 3 D 64331 Weiterstadt Germany www lynx technik com Reference Manual C DA 5005 5 Channel SDI to CVBS Converter CardModule Version 1 0...

Page 2: ...written permission of LYNX Technik AG LYNX Technik AG may have patents patent applications trademarks copyrights or other intellectual property rights covering the subject matter in this document Exce...

Page 3: ...ranty shall not apply to any defect failure or damage caused by improper use or improper or inadequate maintenance and care LYNX Technik shall not be obligated to furnish service under this warranty a...

Page 4: ...s operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful in...

Page 5: ...unctional Diagram 8 Module Layout 8 Connections 10 Video Connections 10 Installation 11 Settings and Control 12 Control Modes 13 Switch Settings 14 Switch Function Detail 15 Factory Preset Condition 1...

Page 6: ...Reference Manual C DA 5005 Version1 0 Page 6 This page is intentionally left blank...

Page 7: ...a variety of features which includes PAL or NTSC operation auto detect Internal color bars Internal 2x over sampling 27MHz Local DIP switches and LED s for control and status monitoring Microprocessor...

Page 8: ...m Figure 1 below is the basic functional diagram for the C DA 5005 CardModule Figure 1 C DA 5005 Functional Diagram Module Layout Figure 2 shows the physical layout of the C DA 5005 CardModule and als...

Page 9: ...Reference Manual C DA 5005 Version1 0 Page 9 Figure 2 Module Layout...

Page 10: ...rd 75 Ohm BNC connectors Connection is self explanatory We recommend the use of high quality video cables for digital video connections to reduce the risk of interference or errors due to excessive ca...

Page 11: ...located b Remove the blank connection panel from the rear of the rack if fitted c Install the rear connection panel using the screws supplied Do not tighten the screws fully d Slide the card module i...

Page 12: ...and controlled locally using integral 8 position dip switch and the multifunction switch or from remote when using one of the optional controllers and control software Once set all settings are automa...

Page 13: ...Test Signal ON and RED for Signal Lost Alarm Enable Mode This mode is used to define which channels are part of the combined alarm indication provided on the single Alarm LED Any channels used or unus...

Page 14: ...form part of the combined alarm reporting for the module Any channel used or unused can be added or removed from the Alarm configuration CHANNEL STATUS MODE Switch Setting Function 1 Toggle on off on...

Page 15: ...he module This is because all settings can be changed from the remote control system This overrides the local dip switches regardless of Switch 1 ON OFF setting To ensure the module reads the local di...

Page 16: ...Switch 3 This is used to select what type signal is output for channels with input signal lost ON selects Color Bars and OFF selects black as output Dip Switch 4 8 CHANNEL STATUS MODE Switch 4 Channel...

Page 17: ...tus Mode Test Signal Color Bars Test Signal OFF Normal operation for all channels All channels Alarm Enabled If this is the mode of operation required then no adjustments are necessary Auto Store If n...

Page 18: ...lower edge of the module which can be seen when the rack front cover is fitted The status of this LED is defined by the alarm enable settings as explained above LED OFF indicates power is lost or ther...

Page 19: ...selected on the control system there is a locate button on the top of the GUI Locate Function in Control System When Locate is selected the status indicator on the GUI and the module LED s will flash...

Page 20: ...NC Impedance 75 Ohms Operating Modes Conversion D A conversion for SDI Signals TV Standard NTSC or PAL Auto detect Test Internal Color Bars Performance Quantization 8 Bits Sampling 27 MHz 2x Over samp...

Page 21: ...Card Frame R CT 5010 Rack Bus Extension for the R FR 5010 Card Frame In combination with R CT 5020 Parts List Due to the very dense design and miniature surface mount technology the module is not fie...

Page 22: ...stributor for assistance We offer a fixed cost service exchange program for defective Series 5000 CardModules out of Warranty Please contact your distributor or check our web site for details on this...

Page 23: ...Technik can be contacted directly using the information below Address LYNX Technik AG Brunnenweg 3 D 64331 Weiterstadt Germany Website www lynx technik com E Mail info lynx technik com LYNX Technik ma...

Page 24: ...Reference Manual C DA 5005 Version1 0 Page 24 This page is intentionally left blank...

Page 25: ...Reference Manual C DA 5005 Version1 0 Page 25 Notes...

Reviews: