7
1. Microphone capsule
2. Indicator light on active microphone
When microphone is active, indicator light switches on
3. Gooseneck 4P connector and fix socket
4. 8-pin connection cable output port
Microphone with 110cm 8P cable for connect microphone branch cable
5. Gooseneck and base fix socket
6. MIC ON/OFF
Press this button to speak (the station will be immediately enabled unless the limit of
simultaneously enabled stations has been reached), Press again to turn off microphone
7. PRIORITY
Press this button on the PRESIDENT station to disable all other speaker stations
6. CONNECTION
Connect the unit to 230 V AC 50/60 Hz mains . Use the connection cables provided to connect the daisy-
chained stations to the 4
BASE INPUT
s (figure 2, ref. 8) as shown in
figure 3
, paying attention not to
connect more than 30 stations to each line and no more than 64 stations altogether.
In any case, the maximum limit of 64 stations cannot be exceeded.
The system can host more than one PRESIDENT station. They can be inserted at any position on the chain.
Fig.3