7.  HOW TO USE THE SYSTEM 

 
User can set the system working mode by the mode knob (

fig1. Ref.3

)  

 

MODES OF OPERATION: 
 

 

FREE MODE 

When this mode is selected, the display will read FREE MODE. In this mode, an unlimited number of 
participants can speak simultaneously. 

 

 

LIMIT MODE 

When  this  mode  is  selected,  this  display  will  show  LIMIT  MODE,  plus  the  number  of  delegates  that 
can  speak  simultaneously.  Once  this  number  of  delegates  is  reached,  no  further  delegates  will  be 
allowed to intervene until the number of active delegate stations again falls below this limit. There are 
4 options for limit number:1/2/3/5 

 

 

8.  PACKAGE CONTENTS

 

 

H-7000: 1x Central unit, 1x  8P main cable, 1x power cable, 1x XLR M-F cable, 2x RCA-TRS cable+, 2x 
fuse (2A), Manual 
H-3800c: 1x Base, 1x Gooseneck microphone,1x connection cable 
H-3800d: 1x Base, 1x Gooseneck microphone,1x connection cable 
 
 

9.  TECHNICAL FEATURES

 

 

Model 

H-7000D 

H-3800c/H-3800d 

BASES 

8P-DIN socket/n°4 BUS 

 

BAL OUT 

Balanced XLR3Male 

 

MIX 

Unbalanced RCA L/R 

  

S/N Radio 

>75 dB 

>75 dB 

Frequency Response 

20 Hz-18 kHz 

20 Hz-18 kHz 

Sensitivity 

 

-44+/-2dB 

T.H.D. 

<0.05% 

<0.05% 

Dimensions (WxHxD) 

482x45x353 mm 
1U standard 19” rack 

Base: 130x160x50 mm  
Gooseneck: 420 mm 

Weight 

5 kg 

0.9 kg 

Power Consumption 

100 W 

1 W 

Power supply 

230 V AC 50/60 Hz 
 

 

18 V DC by 8-PIN cable 

 

 

 

This product complies with Directive 89/336/EEC (Electromagnetic Compatibility) 
and later changes 92/31/EEC and 93/68/EEC, according to the following standards: 

EN 50082-1:1997, EN 55013:1990, EN 55020:1994 
 

furthermore, it complies with Directive 73/23/EEC (Low Voltage) 
and later changes 93/68/CEE, according to the following standard: 

EN 60065:1998 

 

 
 

 
 

 

 

 
 

We maintains a policy of constant research and development, therefore we reserve the right to apply improvements to 
existing equipment without prior notice

.                                                                                                                                                                                      

Summary of Contents for H-3800C

Page 1: ...INSTRUCTION MANUAL Digital Conference System H 7000D H 3800c H 3800d ...

Page 2: ...ION 5 3 FRONT PANEL FUNCTIONS AND CONTROLS H 7000D 5 4 REAR PANEL FUNCTIONS AND CONTROLS H 7000D 6 5 PRESIDENT H 3800c AND DELEGATE H 3800d UNIT FUNCTIONS AND CONTROLS 6 6 CONNECTION 7 7 HOW TO USE THE SYSTEM 9 8 PACKAGE CONTENTS 9 9 TECHNICAL FEATURES 9 ...

Page 3: ...and user s instructions must be followed Sentences preceded by symbol contain important safety instruction Please read it carefully DETAILED SAFETY INSTRUCTIONS Water and moisture This apparatus should not be used near water i e bathtub kitchen sink swimming pools etc Ventilation This apparatus should be placed in a position that doesn t interfere with its correct ventilation This unit for example...

Page 4: ...ug is damaged If liquid has spilled or objects have fallen into the unit The unit has been exposed to rain The unit doesn t operate normally or exhibits a marked change in performance If the product has been dropped or has been damaged in any way Maintenance The user shouldn t attempt maintenance not described in this user s manual All maintenance should be performed by qualified personnel only IM...

Page 5: ...r a maximum of 30 stations on each line The serial connection of each station is achieved through single multicore prerouted cables that may be used either for fixed or mobile systems Main Functions It directly powers and controls 64 microphone stations President station has priority on others Five operating modes FREE MODE LIMIT 1 2 3 5 One microphone input MIC and one line input LINE for externa...

Page 6: ...utput male XLR3 Connect mixer or amplifier to this output 10 DELEGATES Unbalanced signal output RCA Left and right channel 11 TEL IN OUT Connect telephone coincidence to support telephone meeting 12 DATA RJ45 interface use for connect video processor to support video tracking function 13 TREBLE GAIN Rotate this control counterclockwise to emphasize high frequencies 14 AC POWER SOCKET Power 230VAC ...

Page 7: ...tations has been reached Press again to turn off microphone 7 PRIORITY Press this button on the PRESIDENT station to disable all other speaker stations 6 CONNECTION Connect the unit to 230 V AC 50 60 Hz mains Use the connection cables provided to connect the daisy chained stations to the 4 BASE INPUTs figure 2 ref 8 as shown in figure 3 paying attention not to connect more than 30 stations to each...

Page 8: ...TIONS Balanced connection Unbalanced connection Balanced connection with TRS jack Unbalanced connection with TRS jack Balanced connection on EUROBLOC connector Unbalanced connection on EUROBLOC connector RCA Connection ...

Page 9: ...able H 3800d 1x Base 1x Gooseneck microphone 1x connection cable 9 TECHNICAL FEATURES Model H 7000D H 3800c H 3800d BASES 8P DIN socket n 4 BUS BAL OUT Balanced XLR3Male MIX Unbalanced RCA L R S N Radio 75 dB 75 dB Frequency Response 20 Hz 18 kHz 20 Hz 18 kHz Sensitivity 44 2dB T H D 0 05 0 05 Dimensions WxHxD 482x45x353 mm 1U standard 19 rack Base 130x160x50 mm Gooseneck 420 mm Weight 5 kg 0 9 kg...

Reviews: