40
External Power Supply, Optional
VX4 User’s Guide
E-EQ-VX4OGWW-H-ARC
External Power Supply, Optional
The LXE-approved AC Power Adapter is only intended for use in a 25ºC (77ºF) maximum
ambient temperature environment.
1. AC Input Cable
2. DC Output Cable
Figure 36 Optional Power Configuration
In North America, this unit is intended for use with a UL Listed ITE power supply with
output rated 12 – 60 VDC, minimum 3.5 A. Outside North America, this unit is intended for
use with an IEC certified ITE power supply with output rated 12 – 60 VDC, minimum 3.5 A.
The external power supply may be connected to either a 120V, 60Hz supply or, outside North
America, to a 230V, 50Hz supply, using the appropriate detachable cordset. In all cases, connect
to a properly grounded source of supply provided with maximum 15 Amp overcurrent protection
(10 Amp for 230V circuits).
How To: Connect External Power Supply
1.
Turn the VX4 off.
2.
Connect the detachable cordset provided by LXE to the external power supply
(IEC 320 connector).
3.
Plug cordset into appropriate, grounded, electrical supply receptacle (AC mains).
4.
Connect the watertight connector end to the VX4’s Power Connector by aligning
the connector pins to the power connector; push down on the watertight
connector and twist it to fasten securely.
5.
Turn the VX4 on.