Mantel Requirements
No Combustible materials
are permitted lower than
8.5”(inches) above the
opening of the appliance
represented by the hatch
area. A projection ( mantel or
trim) of combustible material
can be no greater than 8”
(inches) at or below the 8.5”
(inches) height. This area is
indicated by the cross hatch
in the illustration.
Caution:
any finish like
stains or clear coatings must
be of a high heat design to
prevent discolouration.
Placement of Appliance Non-Combustible Panels
The factory supplies
two non-combustible
panels that must be
secured in place before
the appliance can be
installed. The 66 1/4”
X 17 ¼” panel is
placed on the base
centered directly
beneath the unit as
shown (A). The 48” x
17” panel must be
secure to the back wall
of the chase so that the
top edge is in line with
the 14” x 14” open for
the venting as shown
(B)
B
A