Safety Notes 

 

Each person which is responsible for the installation, the usage of service of this unit must be 
qualified and has to follow the instruction in this manual.  

Be careful when using the device. You risk an electrical shock from high voltage, if you touch 
the wires! The device has left our company in manufactured proofed state. To maintain this 
status and to ensure a permanent safe operation, it is absolutely necessary to follow the 
safety instructions and warnings in this manual.  

Errors caused by not following these instructions are not covered by the warranty. The 
manufacturer will not accept liability for any resulting defects or problems.  

  Keep the unit away from radiators or other heat sources! 

  If the unit has been exposed to tremendous temperature changes (e.g. after 

transportation), do not turn the device on immediately. The resulting condensation 
could damage the unit. Don’t switch the unit on until the device reaches room 
temperature.  

  This device belongs to protection class I. Therefore, it is imperative that the 

green/yellow wire is connected to the earth contact or plug. The electrical connection 
must be made by a qualified person.  

  Make sure that the cable has never been squeezed or damaged by sharp objects. 

Check the device and the cables regularly.  

  If the cable is damaged, it must be replaced immediately by the manufacturer, its 

service agent or a qualified person in order to avoid danger.  

  Lenses, glasses or UV filters must be replaced if they are visually damaged, or their 

effectiveness is impaired, e.g. by broken glass or by deep scratches.  

  Ensure that wires never come in contact with other wires! Handle the power cord and 

all connections with caution! 

  Make sure that the line voltage is not higher than the voltage specified in this manual.  

  Disconnect the unit from the AC mains when it is not in use or when cleaning it. 

Disconnect the connection only by pulling the cable plug.  

  Using the fixture for the first time, can result in light smoke and odors. This is a 

normal process and does not constitute a defect.  

Risk of burns!  
Do not touch the unit during operation! The housing may reach high temperatures!  

Risk to health!  
Never look directly into the light source. Especially epileptics risk an epileptic shock. 
Disconnect the unit from the AC mains when not in use or when cleaning it.  

Defects caused by modifications of the device by unqualified handling or an unqualified 
person are not covered by the warranty.  

Keep the product away from children and unskilled people.  

There are no wear parts in the device. Maintenance and service must be performed only by 
an authorized service partner.  

 

 

Summary of Contents for B EXPO200MCW

Page 1: ...1 User Manual ...

Page 2: ...2 Table of contents Product introduction 3 Safety 4 Maintenance 6 Installation 7 Control Menu 9 DMX Mode 10 Technical Specifications 12 ...

Page 3: ...ake sure that the packaging is in good condition and that following items will be found in the box B EXPO200MCW fixture 3m DMX cable 1 5m power cable with powercon Safety chain Description of the B EXPO200MCW 1 Mounting bracket 2 Bracket tilt lock 3 B EXPO200MCW 4 Barn door filter frame 5 Ventilation holes 6 PowerTrue1 In 7 OLED Display 8 PowerTrue1 Out 9 5 Pin DMX In 10 Eyebolt 11 5 Pin DMX Out 1...

Page 4: ...r damaged by sharp objects Check the device and the cables regularly If the cable is damaged it must be replaced immediately by the manufacturer its service agent or a qualified person in order to avoid danger Lenses glasses or UV filters must be replaced if they are visually damaged or their effectiveness is impaired e g by broken glass or by deep scratches Ensure that wires never come in contact...

Page 5: ...t to any other wrong power Disconnect the device from main power before open the shield or maintenance The device is designed only for indoor usage please keep it away from moisture Do not expose the device under the sun or directly to any other lighting source Never look directly into the projecting lens when the fixture is power on the light may trigger epileptic seizures in photosensitive perso...

Page 6: ...ty power supply Change a good power cable to try Replace new power supply LED off Temperature protection Fan not working Faulty LED Dimmer and strobe set at 0 Faulty power supply Check the temperature from menu Check the fan speed info from menu Replace new LED Set dimmer channel at 255 and strobe channel at 0 5 Replace new power supply Device not response to DMX Faulty communication IC Faulty dis...

Page 7: ... of used material and the fixture itself Never try to do the installation by yourself if you are not qualified instead you have to instruct a skilled installer Inappropriate installations can cause injuries and or damage of property Spotlight has to be installed outside areas where people can touch it Professional truss system or similar licensed suspension systems have to be used if the spotlight...

Page 8: ...deways like left picture The mounting place must be sufficient stable and be able to support a weight of 10 times of the unit s weight When the fixture is hanged always additionally secure the device with the safety chain fasten the safety rope at a suitable position so that the maximum fall of the projector will be 20 cm ...

Page 9: ...0 255 Information Fan speed Fan1 XXXR Fan1 XXXR Lamp temp XXX C Soft version Settings Fixture Set Temp C F Fahrenheit Celcius Fans Mode Auto High Auto Theatre Theatre ON OFF OFF Hibernation 01 99m OFF Backlight 01 99m 02m Flip Display ON OFF OFF RDM Settings Name Password PID Code Freq Rate 600 Hz 1200 Hz 2000 Hz 2400 Hz 4000 Hz Reload Def Basic Reload ON OFF OFF Password XXX All Reload ON OFF OFF...

Page 10: ...he mode at standard 18 channels mode and there are several models need to be independently controlled we just simply address first fixture at 1 and second fixture at 21 third one at 41 etc If the devices have the same address they will behave synchronically DMX addressing is limited don t set the address so high that without enough control channels for the fixtures Display is flashing when no DMX ...

Page 11: ... for this device come out it can be upgraded simply via a software upgrade box no need to change any mechanical parts The upgrade box is not included in the package if need any further assistance please just contact authorized dealers Hibernation the device will enter sleeping mode if activated after a period of disconnecting DMX signal to save the power consumption and will return immediately as ...

Page 12: ...4 0 lbs Gross weight 11 9 kg 26 2 lbs Mounting options Hanging 3x M12 whole Standing n a 2nd suspension safety wire 1x eye in back of unit to pass carabiner Control Menu control TFT display with 4 buttons Control DMX512 manual In Link XLR 5 pin DMX Mode 1 4 5 channels 16 bit dimming 1 hand locking Manual zoom 15 45 Optical Beam angle 15 45 Light output 15 Lux 5m 4630 lux Lux 10m 1190 lux Lux 15m 5...

Page 13: ...94 Electrical Fixture rated power 200W LED engine 200W 3000 K Input power 100 240V 50 60Hz Auto switching power supply In Link PowerCon TRUE 1 max link current 10A Environmental Cooling Heat pipe air cooling IP rating IP20 Contact Luxibel Bedrijvenpark De Veert 13 004 2830 Willebroek Belgium 32 3 860 76 50 info luxibel com www luxibel com ...