Multipliers for determining the performance with other indoor sections.
LOW CFM
HEATING PERFORMANCE DATA - LOW CFM 1-STAGE OPERATION
OUTDOOR UNIT MODEL NO.
HL8B048F4C
INDOOR COIL MODEL NO.
FC/MC62D + MV20D
AIR TEMP.
ENTERING
OUTDOOR UNIT (°F)
AIR TEMP.
ENTERING
INDOOR COIL (°F)
ID CFM
1025
1075
1125
MBH
COP
KW
MBH
COP
KW
MBH
COP
KW
60
60
40.00
4.31
2.72
40.70
4.65
2.57
41.40
5.04
2.41
70
39.40
3.70
3.12
40.00
4.00
2.93
40.60
4.33
2.75
80
38.70
3.23
3.51
39.30
3.49
3.30
39.90
3.78
3.09
47
60
34.10
3.81
2.62
34.60
4.05
2.50
35.10
4.32
2.38
70
33.40
3.29
2.98
34.00
3.50
2.85
34.60
3.74
2.71
80
32.80
2.87
3.34
33.40
3.07
3.19
34.00
3.28
3.04
40
60
30.80
3.51
2.57
31.20
3.70
2.47
31.60
3.90
2.38
70
30.40
3.04
2.93
30.80
3.21
2.81
31.20
3.40
2.69
80
29.90
2.67
3.28
30.30
2.83
3.14
30.80
3.00
3.01
30
60
–
–
–
–
–
–
–
–
–
70
–
–
–
–
–
–
–
–
–
80
–
–
–
–
–
–
–
–
–
17
60
–
–
–
–
–
–
–
–
–
70
–
–
–
–
–
–
–
–
–
80
–
–
–
–
–
–
–
–
–
10
60
–
–
–
–
–
–
–
–
–
70
–
–
–
–
–
–
–
–
–
80
–
–
–
–
–
–
–
–
–
NOTE:
ALL CAPACITIES ARE NET, WITH INDOOR FAN HEAT ALREADY DEDUCTED. KW VALUES ARE FOR THE SYSTEM (O INDOOR).
Air Handler
Coil
MBH
COP
KW
–
FC/MC62
1.04
0.95
1.09
AHE60D
–
1.01
1.01
0.99
AHV48D
–
1.00
0.95
1.05
AHV60D
–
0.99
0.97
1.02
MV16C
FC/MC48C
1.00
0.96
1.04
MV16C
FC60C
1.01
0.95
1.06
MV20D
FC/MC48D
0.99
0.96
1.04
MV20D
FC/MC60D
1.01
0.94
1.07
MV20D
FC/MC62D
1.00
1.00
1.00
MV20D
FC64D
1.01
1.03
0.98
MX16CN21
FC/MC48C
0.99
0.97
1.02
MX16CN21
FC60C
1.00
0.97
1.04
Furnace
Coil
MBH
COP
KW
T*(8,L)V*C16
FC/MC/PC48C
1.01
0.97
1.05
T*(8,L)V*C16
FC/MC/PC48D
1.01
0.97
1.05
T*(8,L)V*C16
FC/MC/PC60D
1.01
0.94
1.07
T*(8,L)V*C16
FC/MC62D
1.00
0.97
1.04
T*(8,L)V*C16
FC/PC60C
1.01
0.94
1.07
T*(8,L)V*C16
FC64D
1.02
1.01
1.01
T*(8,L)V*C16
UC48C
1.02
0.99
1.04
T*(8,L)V*C16
UC60C
0.99
0.93
1.07
T*(8,L)V*C20
FC/MC/PC48C
1.00
0.95
1.05
T*(8,L)V*C20
FC/MC/PC48D
1.00
0.95
1.05
T*(8,L)V*C20
FC/MC/PC60D
1.01
0.94
1.07
T*(8,L)V*C20
FC/MC62D
1.01
0.97
1.04
T*(8,L)V*C20
FC/PC60C
1.01
0.94
1.07
T*(8,L)V*C20
FC64D
1.02
1.01
1.02
T*(8,L)V*C20
UC48C
1.03
0.99
1.04
T*(8,L)V*C20
UC60C
0.99
0.92
1.07
T*9V*C16
FC/MC/PC48C
1.00
0.94
1.06
T*9V*C16
FC/MC/PC48D
1.00
0.94
1.06
T*9V*C16
FC/MC/PC60D
1.01
0.94
1.08
T*9V*C16
FC/MC62D
1.01
0.97
1.04
T*9V*C16
FC/PC60C
1.01
0.94
1.08
T*9V*C16
FC64D
1.02
1.01
1.02
T*9V*C16
UC48C
1.02
0.98
1.05
T*9V*C16
UC60C
0.99
0.91
1.09
T*9V*C20
FC/MC/PC48C
1.00
0.95
1.05
T*9V*C20
FC/MC/PC48D
1.00
0.95
1.05
T*9V*C20
FC/MC/PC60D
1.01
0.94
1.07
T*9V*C20
FC/MC62D
1.00
0.97
1.04
T*9V*C20
FC/PC60C
1.01
0.94
1.07
T*9V*C20
FC64D
1.02
1.01
1.02
T*9V*C20
UC48C
1.03
0.99
1.04
T*9V*C20
UC60C
1.00
0.93
1.08
T*9V*D20
FC/MC/PC48D
1.00
0.94
1.06
T*9V*D20
FC/MC/PC60D
1.01
0.94
1.08
T*9V*D20
FC/MC62D
1.01
0.98
1.03
T*9V*D20
FC64D
1.02
1.00
1.02
T*9V*D20
UC48D
1.03
0.99
1.04
T*9V*D20
UC60D
0.99
0.93
1.07
TM8X080C16MP11
FC/MC/PC48C
0.99
0.96
1.04
TM8X080C16MP11
FC/MC/PC48D
0.99
0.96
1.04
TM8X080C16MP11
FC/MC/PC60D
1.01
0.95
1.05
Continued on next page.
Furnace
Coil
MBH
COP
KW