44
Johnson Controls Unitary Products
1109434-FTG-A-0714
COP equals MBH output divided by (total KW input x 3.412).
HSPF (Heating Seasonal Performance Factor) is the total heating output during a normal annual usage period for heating divided by the total electric power input
during the same period.
— = Not Applicable.
PSC furnaces, such as the TG8S, TGLS, and TG9S, use Coil Only Ratings.
ACCESSORIES & APPLICATIONS
Refer to Price Manual for specific model numbers.
Long Lineset Applications -
For installations with more than
75' of equivalent lineset length, refer to the current version of
the
Piping Application Guide 247077-UAD-H-0209
, available
in the Application Bulletins section on UPGnet.
Start Assist Kit (S1-2SA067*) -
Provides increased starting
torque for areas with low voltage. See Hard Start Kit Accessory
Installation Manual for Hard Start Kit part number for each
model.
TXV Kits -
S1-1TVM series thermal expansion valves precisely
meter refrigerant for optimum performance over a wide range of
conditions. See System Charge table for TXV part number for
each model.
Bonnet Sensor (S1-2SB13700124) -
The bonnet sensor is
used to sense plenum temperature, and is optional with a gas
or oil back-up heat source. Compatible only with 13 SEER and
higher heat pumps.
Dehumidistat (S1-2HU16700124) -
Provides increased dehu-
midification when matched with variable speed furnace or air
handler.
Heat Pump Risers -
(S1-52635389000, S1-52635390000,
S1-52635391000) - 3", 6", or 12" risers mount easily in compos-
ite base pan recesses, ensuring the unit stays clear of snow
and ice build-up in harsh winter weather.
Thermostats
- Compatible thermostat controls are available
through accessory sourcing. For optimum performance, these
outdoor units are fully compatible with the Residential Touch-
screen Communicating Control (Zoning and Non-Zoning ver-
sions). For more information, see the Residential Control
Systems section of the Product Equipment Catalog.
HL8B060F4(C)
TM9X100C20MP11
FC/MC62D
1
985
40.5
–
–
3.00
2
1550
57.5
38.0
9.25
3.56
2*
985
58.0
36.8
9.15
2.76
TM9X100C20MP11
FC64D
1
980
41.0
–
–
3.10
2
1550
57.5
38.5
9.30
3.66
2*
980
58.5
37.4
9.25
2.82
TM9X100C20MP11
UC60D
1
960
40.0
–
–
2.82
2
1525
57.0
38.0
9.10
3.42
2*
960
57.5
37.2
9.00
2.62
TM9X120D20MP11
FC/MC/PC60D
1
980
40.5
–
–
2.90
2
1550
57.0
38.5
9.20
3.46
2*
980
57.5
37.6
9.05
2.66
TM9X120D20MP11
FC/MC62D
1
980
40.5
–
–
3.00
2
1550
57.5
38.0
9.25
3.58
2*
980
58.0
36.8
9.15
2.76
TM9X120D20MP11
FC64D
1
960
41.0
–
–
3.06
2
1525
57.5
38.0
9.30
3.66
2*
960
58.5
37.4
9.25
2.78
TM9X120D20MP11
UC60D
1
980
40.0
–
–
2.90
2
1550
57.0
38.0
9.15
3.42
2*
980
58.0
36.8
9.10
2.70
1. MC coils available with a factory installed horizontal drain pan. See price pages for specific model number.
2. Heating MBH based on AHRI standards of 70°F DB (Dry Bulb) entering indoor air, 72% RH (Relative Humidity) outdoor air with 25 feet of interconnecting pip-
ing and no supplemental electric heat operation.
3. High Efficiency Motor Furnaces have B.O.D (Blower on Delay) standard.
* Notates “Hot Heat Pump” performance. These ratings are not AHRI listed.
HEATING CAPACITY - With High Efficiency Motor Furnaces (Continued)
UNIT
MODEL
FURNACE
MODEL
COIL
1
MODEL
HEATING
2
STAGE
RATED
CFM
NET MBH
HSPF
COP @ 47°F
47°F OD
17°F OD
18 SEER HP WITH HIGH EFFICIENCY MOTOR FURNACES
3
Application Limits
Maximum Lineset Equivalent Length
75 Ft
Outdoor Ambient Temperature Limits
Cooling Operation
Maximum DB
115°F
Minimum DB
50°F
Heating Operation
Maximum DB
75°F
Minimum DB
-10°F