Multipliers for determining the performance with other indoor section.
HIGH CFM
HEATING PERFORMANCE DATA - HIGH CFM 2-STAGE OPERATION
OUTDOOR UNIT MODEL NO.
HL8B024F4C
INDOOR COIL MODEL NO.
FC/MC48D + MV12D
AIR TEMP.
ENTERING
OUTDOOR UNIT (°F)
AIR TEMP.
ENTERING
INDOOR COIL (°F)
ID CFM
800
900
1000
MBH
COP
KW
MBH
COP
KW
MBH
COP
KW
60
60
28.7
4.81
1.75
29.2
5.24
1.63
29.6
5.76
1.51
70
28.1
4.03
2.04
28.5
4.47
1.87
28.9
5.02
1.69
80
27.4
3.45
2.33
27.7
3.87
2.10
28.1
4.42
1.87
47
60
24.2
4.25
1.67
24.6
4.67
1.54
24.9
5.19
1.41
70
23.7
3.63
1.91
24.0
4.00
1.76
24.3
4.44
1.61
80
23.2
3.14
2.16
23.4
3.46
1.98
23.7
3.85
1.80
40
60
21.6
3.96
1.60
22.0
4.34
1.49
22.5
4.81
1.37
70
21.3
3.44
1.81
21.6
3.75
1.69
21.9
4.11
1.56
80
21.0
3.03
2.03
21.1
3.27
1.89
21.3
3.57
1.75
30
60
20.7
3.51
1.72
21.0
3.82
1.61
21.3
4.16
1.50
70
20.3
3.04
1.96
20.5
3.30
1.82
20.8
3.57
1.70
80
20.0
2.67
2.19
20.1
2.88
2.05
20.2
3.11
1.90
17
60
17.0
3.23
1.54
17.4
3.46
1.47
17.7
3.69
1.41
70
16.5
2.84
1.70
16.8
3.00
1.64
17.1
3.20
1.57
80
16.0
2.50
1.87
16.2
2.64
1.80
16.5
2.79
1.73
10
60
15.1
2.85
1.55
15.2
3.04
1.47
15.4
3.25
1.39
70
14.7
2.60
1.65
14.8
2.75
1.58
15.0
2.94
1.50
80
14.2
2.37
1.76
14.5
2.51
1.69
14.7
2.67
1.61
NOTE:
ALL CAPACITIES ARE NET, WITH INDOOR FAN HEAT ALREADY DEDUCTED. KW VALUES ARE FOR THE SYSTEM (O INDOOR).
Air Handler
Coil
MBH
COP
KW
–
FC/MC/PC48
1.03
0.89
1.16
AHV24B
–
0.98
0.88
1.11
AHV30B
–
0.99
0.91
1.10
AHV36C
–
0.99
0.94
1.06
MV12B
FC/MC43B
1.00
0.95
1.06
MV12D
FC/MC48D
1.00
1.00
1.00
MV12D
FC/MC60D
0.99
0.98
1.01
Furnace
Coil
MBH
COP
KW
T*(8,L)V*A12
FC/MC/PC37A
0.99
0.93
1.07
T*(8,L)V*B12
FC/MC/PC43B
0.99
0.94
1.05
T*(8,L)V*C16
FC/MC/PC43C
0.99
0.94
1.05
T*9V*A10
FC/MC/PC37A
1.01
0.91
1.11
T*9V*B12
FC/MC/PC43B
1.00
0.94
1.06
T*9V*C16
FC/MC/PC48C
1.01
0.98
1.03
T*9V*C16
FC/PC60C
1.01
0.98
1.03
T*9V*C16
UC48C
1.01
1.01
1.00
T*9V*C16
UC60C
1.01
0.98
1.03
T*9V*C20
FC/MC/PC43C
1.01
0.98
1.03
T*9V*C20
FC/MC/PC48C
1.01
0.98
1.03
T*9V*C20
UC48C
1.01
1.01
1.00
TM8X080C16MP11
FC/MC/PC43C
1.01
0.92
1.10
TM8X080C16MP11
FC/MC/PC48C
1.01
0.93
1.09
TM8X080C16MP11
FC/PC60C
1.01
0.93
1.08
TM8X080C16MP11
UC48C
1.02
0.96
1.06
TM8X080C16MP11
UC60C
1.01
0.93
1.08
TM8X100C16MP11
FC/MC/PC43C
1.01
0.92
1.10
TM8X100C16MP11
FC/MC/PC48C
1.01
0.93
1.09
TM8X100C16MP11
FC/PC60C
1.01
0.93
1.08
TM8X100C16MP11
UC48C
1.02
0.96
1.06
TM8X100C16MP11
UC60C
1.01
0.93
1.08
TMLX080C16MP11
FC/MC/PC43C
1.01
0.92
1.10
TMLX080C16MP11
FC/MC/PC48C
1.01
0.93
1.09
TMLX080C16MP11
FC/PC60C
1.01
0.93
1.08
TMLX080C16MP11
UC48C
1.02
0.96
1.06
TMLX080C16MP11
UC60C
1.01
0.93
1.08
TMLX100C16MP11
FC/MC/PC43C
1.01
0.92
1.10
TMLX100C16MP11
FC/MC/PC48C
1.01
0.93
1.09
TMLX100C16MP11
FC/PC60C
1.01
0.93
1.08
TMLX100C16MP11
UC48C
1.02
0.96
1.06
TMLX100C16MP11
UC60C
1.01
0.93
1.08
Furnace
Coil
MBH
COP