Maintenance
WARNING!
Before carrying out any work, always disconnect the LUX ELEMENTS
®
-TUB-PUMP from the power supply and ensure that it cannot
be switched on again by other persons.
The system is largely maintenance-free. However, soap residues should be removed from the interior of the tank every 2 – 3
weeks. To do so, simply lift the cover off and then clean the inside carefully with a paintbrush or some other type of brush.
ATTENTION!
Do not use aggressive drain cleaners!
If the hydraulic system is blocked, pull the red fixing element upwards and take it out. Next, gently loosen the hydraulic system
and remove it. After cleaning, make sure that when you reinsert it, the swing-type check valve and the two seals are firmly in place.
Finally, insert the red fixing element.
Technische Daten
LUX ELEMENTS TUB
®
-PUMP-S … LUX ELEMENTS TUB
®
-PUMP …
DN 25 25
IP 68 IP 68
P1 [W] 30 65
U [V] 1/N/PE ~230 1/N/PE ~230
f [Hz] 50 50
l [A] 0,20 0,44
[min
-1
] 3000 3000
S2 30 min 30 min
S3 30% (3/7 min operation/pause) 30% (3/7 min operation/pause)
H max [m] 1,3 2,3
Q max [l/min] 25 30
Technical data
Lifting height H [m]
0,1 0,75 1 1,5 2
Flow rate Q [l/s]
LUX ELEMENTS TUB
®
-PUMP-S …
0,43
0,38 0,27
Flow rate Q [l/s]
LUX ELEMENTS TUB
®
-PUMP …
0,77 0,67 0,52 0,33
Upper layer thickness (tile + adhesive)
LUX ELEMENTS TUB
®
-PUMP-S … LUX ELEMENTS TUB
®
-PUMP …
Shower base element
13 – 18 mm 13 – 18 mm
Stainless steel cover
10 mm 10 mm