Product description
Scope of delivery
8
Vacuum Regulator for Chlorine Gas
C 2700-V
© Lutz-Jesco GmbH 2016
Operating Instructions
BA-21210-02-V05
4 Product description
4.1 Scope of delivery
Carefully check the delivery prior to installation and refer to the delivery
note to ensure the delivery is complete and to check for any transport
damage. Contact the supplier and/or carrier regarding any questions
concerning the delivery and/or transport damage. Do not operate defec-
tive devices.
The device is assembled ready-to-install. All the openings are closed by
transportation locks.
The scope of delivery includes:
Vacuum regulator with inlet valve and integrated safety valve.
Pressure gauge (optional)
Flange connection on chlorine gas input including screws and seal
(optional)
5-m tube with mounting material as blow-off line
Ammonia solution for leakage test
Operating manual
4.2 Design and function
4.2.1 Design of a vacuum chlorinator
Fig. 4-1: Design of a vacuum chlorinator
The chlorine gas is under overpressure when it comes from the chlorine
barrels. The vacuum regulator (
) only allows the chlorine to flow if
there is a suctioning vacuum at the device’s output. Therefore, if a line
behind the vacuum regulator breaks, there is no need to fear a chlorine
leak.
The dosing device comprises a flow meter (
) with manual control
valve, and also often an electrically actuated control valve (
) and a
pressure regulator (
).
The injector (
) creates the vacuum based on the Venturi effect and
mixes the chlorine gas in the motive water flow. If the water does not
move, chlorination is stopped immediately. Then the non-return valve
(
) prevents water from penetrating into the dosing devices.
4.2.2 Structure of the device
Fig. 4-2: Structure of the device
Cl
2
H
2
O
M
1
2
3
44
6
5
Item
Description
1
Input
2
Pressure gauge (optional)
3
Safety valve output
4
Plug
5
Output
2
5
1
4
3