GB
40
3.4.1.4 Conversion of the flow volume in kilograms via the correction factor
For special applications, the flow meter is able to display the measured volume in a unit of mass such as kilograms.
The correlation between volume V and mass m is ascertained using density
r
.
m
=
ρ
• V
If the correction factor for volume measurement is known (see chapter C 3.3.1 or correction factor diagram 3),
this is offset with the density
r
. Convert the correction factor according to the below formula
k
1
: Correction factor after calibration
k
2
: Correction factor for display of the unit of mass
r
: Fluid density
k
2
=
ρ
• k
1
Example
Operation
Display
Enter the calculated correction factor k
2
The entered correction factor flashes
The entered correction factor flashes
+
The unit of volume (litres or gallons) displayed on the flow meter is now no longer valid.
Recommendation: Cover over the displayed unit of volume using a foil indicating the valid unit of mass.
C. Operating unit