Installation Instructions

Occupant Copy

System Communications

Communication between Wallstation and Control Unit must be established prior to normal operation. Follow these steps:

1.

Put the Wallstation in setup mode

(only one Wallstation can be in setup mode at a time).

Press and hold the buttons indicated (see examples below) for about 3 seconds, until the LED(s) start cycling.

Note: SG-3WD

can control 2 separate groups of window treatment zones. Only ONE (1) set of button controls can be in setup mode

at a time.

Press and
hold here for
setup mode

LEDs cycle

Press and
hold here for
setup mode

Press and
hold here for
setup mode

SG - 2W

SG - 3W

SG - 3WRL

LEDs cycle

LEDs cycle

Press and
hold here for
setup mode

Press and hold
here for setup
mode (Group 2)

Press and hold
here for setup
mode (Group 1)

SG - 5WRL

SG - 3WD

LEDs cycle

LEDs cycle

030747b  8/28/02  10:12 AM  Page 6

Summary of Contents for seeTouch SG-2W

Page 1: ...LUTRON SG 2W SG 3W SG 3WRL SG 3WD SG 5WRL TM Window Treatment Wallstations for use with 3000 Series and 4000 Series systems 030747b 8 28 02 10 12 AM Page 1 ...

Page 2: ...ons will not function correctly with Control Units with lower software revisions Button Functionality Pressing the Open Close or Preset button will cause the window treatment to move to the selected oosition Pressing the same Open Close or Preset button a second time while the window treatments are moving will sto the window treatments Open Pressing the Open button once will cause the window treat...

Page 3: ...Unit by using Class 2 PELV wiring methods per the National Electrical Code Check with your local electrical inspector for the local code requirements and wiring practices allowed in your area Use only a cloth with warm water and mild soap to clean faceplates no chemical cleaners Wiring Notes System Maximums 8 Unique GRAFIK Eye addresses per system 16 Wallstations per system 8 GRAFIK Eye Sivoia Con...

Page 4: ... Your Wallstation is factory set for the backlight to be On The backlight can be switched on or off by setting DIP switch 10 4 Remove the faceplate adapter if applicable and button assembly from the Wallstation to access DIP switches 1 Turn power Off Proper wiring of Wallstations is dependent upon the GRAFIK Eye Control System that is providing power GRAFIK Eye 3000 Series and GRAFIK Eye 4000 Seri...

Page 5: ... 4 of the Wallstation s terminal block Shielding must be connected as shown but do not connect to Earth Ground or Wallstation Two 12 AWG 2 5 mm2 power wires will not fit in the terminal blocks however 12 AWG 2 5 mm2 is necessary due to voltage drop on the wire Use the diagram shown at right to make the connections in the wallbox 8 Mount Wallstations as shown below Attach faceplate by pressing in a...

Page 6: ...r about 3 seconds until the LED s start cycling Note SG 3WD can control 2 separate groups of window treatment zones Only ONE 1 set of button controls can be in setup mode at a time Press and hold here for setup mode LEDs cycle Press and hold here for setup mode Press and hold here for setup mode SG 2W SG 3W SG 3WRL LEDs cycle LEDs cycle Press and hold here for setup mode Press and hold here for se...

Page 7: ... setup mode Press and hold the buttons indicated in Step 1 for about 3 seconds until the scene LEDs stop cycling 2 Identify the Control Unit s to be controlled by the Wallstation All Units must be addressed To add an individual window treatment zone from a Control Unit Press the ZONE button for the window treatment zone to be controlled by the Wallstation The entire column of LEDs of this zone wil...

Page 8: ...ate to state Some states do not allow limitations on how long an implied warranty lasts so the above limitation may not apply to you Some states do not allow the exclusion or limitation of incidental or consequential damages so the above limitation or exclusion may not apply to you These products may be covered under one or more of the following U S patents 4 835 343 4 924 349 DES 422 567 DES 436 ...

Reviews: