background image

®

Job Name:

Job Number:

Model Numbers:

Page

S P E C I F I C AT I O N   S U B M I T TA L

LOS-CUS   6

09.04.08

Occupant Sensors

LOS-CUS Series

Sensors

Installation

N

No

orrm

ma

all  M

Mo

ou

un

nttiin

ng

g

Twist and lock threaded mounting post onto cover
plate. Drill through ceiling tile with assembly, using
cutter end of the threaded mounting post. Secure
with washer and nut.

Cutter end

Mounting

M

Mo

ou

un

nttiin

ng

g  tto

o  N

No

on

n--S

Stta

an

nd

da

arrd

d  C

Ce

eiilliin

ng

g  o

orr  F

Fiix

xttu

urre

e

Mount twist-lock cover plate using mounting
screws, nuts, and washers (included). Drill/punch
wire routing hole through ceiling tile at center of
cover plate.

Mounting Plate Dimensions

4.2 in.
(106.6 mm)

2.5 in.

(63 mm)

.52 in.

(13.3 mm)

13/16 in (21 mm)

Wire Lengths

# Sensors

1

2

3

1

2

1

# Aux. PP

0

0

0

1

1

2

22 AWG

750 ft. 375 ft. 250 ft. 375 ft. 250 ft. 250 ft.

0.5 mm

2

365 m 180 m 120 m 90 m

120 m 120 m

20 AWG

1200 ft. 600 ft. 400 ft. 600 ft. 400 ft. 400 ft.

0.75 mm

2

730 m 365 m 240 m 365 m 240 m 365 m

18 AWG

2400 ft. 1200 ft. 800 ft. 1200 ft. 800 ft. 800 ft.

6

Summary of Contents for LOS-CUS-500-WH

Page 1: ...2 4 to 3 7 m ceiling Affords choice of turning lights off or dimming to a preset level in the unoccupied state when integrated with a Lutron system Models Available C Ca at t N No o C Co ollo or r C C...

Page 2: ...nic motion detected Housing Rugged high impact injection molded plastic Color coded leads 6 in 15 cm Power Operating voltage 20 24 V PELV Class 2 USA low voltage Operating current 33 mA nominal Contro...

Page 3: ...ting controller Note Power pack may be required when interfaced to lighting control system see below Power Supply Options Lutron Lighting Control System Power Pack Required Digital microWATTTM No EcoS...

Page 4: ...ed Red 1 to 3 Sensors with Power Pack Switching Multiple Loads with Auxiliary Power Packs Hot Neutral Hot Manual switch off optional Lighting Load Lighting Load Power Pack Auxiliary Power Pack Red Red...

Page 5: ...80 occupant sensor 500 and 1000 models place the sensor on the same wall as the doorway so that traffic in a hallway will not affect the sensor otherwise place in center of room Closely follow the dia...

Page 6: ...n n S St ta an nd da ar rd d C Ce eiilliin ng g o or r F Fiix xt tu ur re e Mount twist lock cover plate using mounting screws nuts and washers included Drill punch wire routing hole through ceiling t...

Page 7: ...Compensation No Normal Yes Use increased turn on threshold Adjust Timer Automatically Use Manual Setting No adjustment Adjust Sensitivity Automatically Adjust Sensitivity Manually 1 Remove the retaine...

Reviews: